Finite element analysis of donning procedure of a prosthetic transfemoral socket D Lacroix, JF Ramírez Patiño Annals of biomedical engineering 39, 2972-2983, 2011 | 104 | 2011 |
Micro-arc oxidation coating on porous magnesium foam and its potential biomedical applications JM Rúa, AA Zuleta, J Ramírez, P Fernández-Morales Surface and Coatings Technology 360, 213-221, 2019 | 47 | 2019 |
Incidence of the boundary condition between bone and soft tissue in a finite element model of a transfemoral amputee JF Ramírez, JA Vélez Prosthetics and orthotics international 36 (4), 405-414, 2012 | 41 | 2012 |
Numerical modeling and simulation of uniaxial compression of aluminum foams using FEM and 3D-CT images JF Ramírez, M Cardona, JA Velez, I Mariaka, JA Isaza, E Mendoza, ... Procedia Materials Science 4, 227-231, 2014 | 32 | 2014 |
Influence of gait cycle loads on stress distribution at the residual limb/socket interface of transfemoral amputees: a finite element analysis SC Henao, C Orozco, J Ramírez Scientific Reports 10 (1), 4985, 2020 | 30 | 2020 |
Sistema modular de robótica colaborativa aplicado en educación JA Jiménez Builes, JF Ramírez Patiño, JJ González España Revista Facultad de Ingeniería Universidad de Antioquia, 163-172, 2011 | 21 | 2011 |
Analysis of bone demineralization due to the use of exoprosthesis by comparing Young’s Modulus of the femur in unilateral transfemoral amputees JF Ramírez, JA Isaza, I Mariaka, JA Vélez Prosthetics and orthotics international 35 (4), 459-466, 2011 | 18 | 2011 |
Experimental assessment of friction coefficient between polypropylene and human skin using instrumented sclerometer JF Ramírez, JJ Pavón, A Toro Proceedings of the Institution of Mechanical Engineers, Part J: Journal of …, 2015 | 17 | 2015 |
Unidades Hounsfield como instrumento para la evaluación de la desmineralización ósea producida por el uso de exoprótesis JF Ramírez Patiño, JA Isaza, I Mariaka, JA Vélez Zea Revista Facultad de Ingeniería Universidad de Antioquia, 159-167, 2013 | 17 | 2013 |
DESIGN CYCLE OF A ROBOT FOR LEARNING AND THE DEVELOPMENT OF CREATIVITY IN ENGENEERING JS Álvarez Chavarría, JA Jiménez Builes, JF Ramírez Patiño Dyna 78 (170), 51-58, 2011 | 16* | 2011 |
Robótica educativa: estrategias activas en ingeniería J Jiménez, D Ovalle, J Ramírez Editorial Universidad Nacional de Colombia, 2010 | 11 | 2010 |
Comfort perception assessment in persons with transfemoral amputation JF Ramírez-Patiño, DF Gutiérrez-Rôa, AA Correa-Espinal Dyna 82 (191), 194-202, 2015 | 10 | 2015 |
Algorithm for the prediction of the reactive forces developed in the socket of transfemoral amputees JF Ramírez, E Jaramillo Muñoz, JA Vélez Dyna 79 (173), 89-95, 2012 | 10 | 2012 |
Ultra-hydrophobic aluminum foam development for potential application in continuous water-oil separation processes L Álvarez-Gil, J Ramirez, P Fernandez-Morales Surfaces and Interfaces 26, 101362, 2021 | 9 | 2021 |
Tailoring adaptive bioresorbable Mg-based scaffolds with directed plasma nanosynthesis for enhanced osseointegration and tunable resorption VM Posada, A Civantos, J Ramírez, P Fernández-Morales, JP Allain Applied Surface Science 550, 149388, 2021 | 9 | 2021 |
Influence of indentation test factors on the mechanical response of the skin JA Isaza L, D Lacroix, J Ramírez, JC Salcedo-Reyes Universitas Scientiarum 24 (1), 49-72, 2019 | 8 | 2019 |
Caracterización de propiedades mecánicas mediante análisis inverso del Método de los Elementos Finitos combinado con ensayo de indentación J ISAZA, I MARIAKA, J Ramírez Dyna 80 (179), 126-133, 2013 | 8 | 2013 |
Nuevos modelos de aprendizaje y desarrollo de la creatividad usando agentes robóticos JJ González España, JA Jiménez Builes, JF Ramírez Patiño Dyna 77 (162), 205-212, 2010 | 8 | 2010 |
Coefficient of friction measurements on transfemoral amputees SC Henao, S Cuartas-Escobar, J Ramírez Biotribology 22, 100126, 2020 | 7 | 2020 |
Incidence of temperature and indenter diameter on the mechanical response of skin during indentation test J Isaza, J Ramirez Procedia Engineering 110, 45-50, 2015 | 7 | 2015 |