关注
Beungyong Park
Beungyong Park
Department of Building and Plant Engineering, Hanbat National University
在 hanbat.ac.kr 的电子邮件经过验证 - 首页
标题
引用次数
引用次数
年份
Numerical evaluation of influence of door opening on interzonal air exchange
S Lee, B Park, T Kurabuchi
Building and environment 102, 230-242, 2016
442016
Experimental and numerical study on the application of low-temperature radiant floor heating system with capillary tube: Thermal performance analysis
J Cho, B Park, T Lim
Applied Thermal Engineering 163, 114360, 2019
402019
Thermal performance evaluation of a data center cooling system under fault conditions
J Cho, B Park, Y Jeong
Energies 12 (15), 2996, 2019
262019
Effect of under-floor air distribution system to prevent the spread of airborne pathogens in classrooms
CH Cheong, B Park, SR Ryu
Case Studies in Thermal Engineering 28, 101641, 2021
222021
Development of an independent modular air containment system for high-density data centers: Experimental investigation of row-based cooling performance and PUE
J Cho, B Park, S Jang
Energy 258, 124787, 2022
212022
Investigation of the energy saving efficiency of a natural ventilation strategy in a multistory school building
B Park, S Lee
Energies 13 (7), 1746, 2020
202020
Thermal performance assessment of flexible modular housing units for energy independence following disasters
B Park, J Cho, Y Jeong
Sustainability 11 (20), 5561, 2019
192019
Ventilation systems to prevent food odour spread in high-rise residential buildings
T Kim, BY Park, CH Cheong
Indoor and Built Environment 21 (2), 304-316, 2012
152012
Analysis of outdoor thermal environment in space arrangement of apartment complex in summer by actual measurement and CFD simulation
JS Kim, HL Piao, BY Park, TY Kim, SB Lee
Journal of the Architectural Institute of Korea 26 (5), 335-342, 2010
132010
Evaluation of thermal characteristics on a multi-sheet-type radiant panel heating system
S Lee, B Park, J Kim, S Kato
Journal of Building Engineering 8, 48-57, 2016
122016
Thermal comfort analysis of combined radiation-convection floor heating system
B Park, SR Ryu, CH Cheong
Energies 13 (6), 1420, 2020
102020
Technical feasibility study of a compact desiccant-based outdoor air system using cogenerated hot water
B Park, S Lee, S Kato
Applied Thermal Engineering 106, 968-980, 2016
102016
Investigation on heat and mass transfer characteristics for a zeolite-coated heat exchanger using comparatively low-temperature energy: Heating humidification mode and cooling …
B Park, S Lee
Indoor and Built Environment 30 (9), 1486-1502, 2020
82020
Design method to prevent airborne infection in an emergency department
CH Cheong, B Park, S Lee
Journal of Asian Architecture and Building Engineering 17 (3), 581-588, 2018
82018
Effects of microencapsulated phase change material on indoor thermal comfort and energy consumption
B Park, CH Cheong, DY Park, SR Ryu
Case Studies in Thermal Engineering 41, 102681, 2023
72023
A comparative CFD study of two air distribution systems with hot aisle containment in high-density data centers
J Cho, J Woo, B Park, T Lim
Energies 13 (22), 6147, 2020
72020
하절기 아파트단지의 열환경 실측과 CFD 를 이용한 해석방법검증에 관한 연구
김주수, 박화란, 박병용, 김태연, 이승복
대한건축학회지 26 (5), 335-342, 2010
72010
How can we simulate the Bi-directional flow and time-variant heat exchange ventilation system?
Y Choi, B Park, S Park, D Song
Applied Thermal Engineering 181, 115948, 2020
52020
Developing energy based benchmark model and detailed energy analysis through school statistical data and field surveys
B Park, BU Kang, DY Park
Heliyon 8 (10), 2022
42022
Air conditioner and method for controlling an air conditioner
P Beungyong, S Hwang, J Lee, JS Kim, HAM Seaunglok
US Patent 10,436,456, 2019
42019
系统目前无法执行此操作,请稍后再试。