关注
John D. DesJardins
John D. DesJardins
在 clemson.edu 的电子邮件经过验证
标题
引用次数
引用次数
年份
Displaced intra-articular fractures of the distal radius: The effect of fracture displacement on contract stresses in a cadaver model
ME Baratz, JD Des Jardins, DD Anderson, JE Imbriglia
The Journal of hand surgery 21 (2), 183-188, 1996
3621996
Hamstrings cocontraction reduces internal rotation, anterior translation, and anterior cruciate ligament load in weight‐bearing flexion
BA MacWilliams, DR Wilson, JD DesJardins, J Romero, EYS Chao
Journal of Orthopaedic Research 17 (6), 817-822, 1999
3071999
The acromioclavicular capsule as a restraint to posterior translation of the clavicle: a biomechanical analysis
JJ Klimkiewicz, GR Williams, JS Sher, A Karduna, JD Des Jardins, ...
Journal of shoulder and elbow surgery 8 (2), 119-124, 1999
2961999
The use of a force-controlled dynamic knee simulator to quantify the mechanical performance of total knee replacement designs during functional activity
JD DesJardins, PS Walker, H Haider, J Perry
Journal of biomechanics 33 (10), 1231-1242, 2000
1772000
UHMWPE wear against roughened oxidized zirconium and CoCr femoral knee components during force-controlled simulation
JD DesJardins, B Burnikel, M LaBerge
Wear 264 (3-4), 245-256, 2008
812008
Lockable implants
EM Lucas, JD DesJardins, KJ Chillag, FR Voss
US Patent 9,393,123, 2016
782016
A direct comparison of patient and force-controlled simulator total knee replacement kinematics
JD DesJardins, SA Banks, LC Benson, T Pace, M LaBerge
Journal of biomechanics 40 (15), 3458-3466, 2007
692007
Comparison of polyethylene tibial insert damage from in vivo function and in vitro wear simulation
MK Harman, J DesJardins, L Benson, SA Banks, M LaBerge, WA Hodge
Journal of Orthopaedic Research 27 (4), 540-548, 2009
662009
Effect of stair descent loading on ultra-high molecular weight polyethylene wear in a force-controlled knee simulator
LC Benson, JD DesJardins, MK Harman, M LaBerge
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2002
652002
Development of luminescent pH sensor films for monitoring bacterial growth through tissue
F Wang, Y Raval, H Chen, TRJ Tzeng, JD DesJardins, JN Anker
Advanced healthcare materials 3 (2), 197-204, 2014
632014
Increased total knee arthroplasty ultra-high molecular weight polyethylene wear using a clinically relevant hyaluronic acid simulator lubricant
J DesJardins, A Aurora, SL Tanner, TB Pace, KB Acampora, M LaBerge
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2006
612006
Reduction of total knee replacement wear with vitamin E blended highly cross-linked ultra-high molecular weight polyethylene
C Vaidya, E Alvarez, J Vinciguerra, DA Bruce, JD DesJardins
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2011
572011
Effects of in vitro wear of machined and molded UHMWPE tibial inserts on TKR kinematics
LC Benson, JD DesJardins, M LaBerge
Journal of Biomedical Materials Research: An Official Journal of The Society …, 2001
492001
A comparison of onlay versus inlay glenoid component loosening in total shoulder arthroplasty
JR Gagliano, SM Helms, GP Colbath, BT Przestrzelski, RJ Hawkins, ...
Journal of Shoulder and Elbow Surgery 26 (7), 1113-1120, 2017
452017
The quantification of physiologically relevant cross-shear wear phenomena on orthopaedic bearing materials using the MAX-shear wear testing system
MR Gevaert, M LaBerge, JM Gordon, JD DesJardins
432005
Effects of patient and surgical alignment variables on kinematics in TKR simulation under force-control
H Haider, P Walker, J DesJardins, G Blunn
Journal of ASTM International 3 (10), JAI100248, 2006
352006
Implantable strain sensor to monitor fracture healing with standard radiography
H Pelham, D Benza, PW Millhouse, N Carrington, M Arifuzzaman, ...
Scientific Reports 7 (1), 1489, 2017
322017
A repeatable alignment method and local coordinate description for knee joint testing and kinematic measurement
BA MacWilliams, JD DesJardins, DR Wilson, J Romero, EYS Chao
Journal of biomechanics 31 (10), 947-950, 1998
311998
Strength testing of definitive transtibial prosthetic sockets made using 3D-printing technology
EA Nickel, KJ Barrons, MK Owen, BD Hand, AH Hansen, JD DesJardins
JPO: Journal of Prosthetics and Orthotics 32 (4), 295-300, 2020
302020
Lockable knee implants and related methods
EM Lucas, JD DesJardins, KJ Chillag, FR Voss
US Patent 9,072,606, 2015
292015
系统目前无法执行此操作,请稍后再试。
文章 1–20