Accelerated edge-preserving image restoration without boundary artifacts A Matakos, S Ramani, JA Fessler IEEE transactions on image processing 22 (5), 2019-2029, 2013 | 89 | 2013 |
In-vivo validation of spatially correct three-dimensional reconstruction of human coronary arteries by integrating intravascular ultrasound and biplane angiography GD Giannoglou, YS Chatzizisis, G Sianos, D Tsikaderis, A Matakos, ... Coronary artery disease 17 (6), 533-543, 2006 | 57 | 2006 |
In-vivo accuracy of geometrically correct three-dimensional reconstruction of human coronary arteries: is it influenced by certain parameters? YS Chatzizisis, GD Giannoglou, A Matakos, C Basdekidou, G Sianos, ... Coronary artery disease 17 (6), 545-551, 2006 | 31 | 2006 |
Estimation of geometrically undistorted B0 inhomogeneity maps A Matakos, J Balter, Y Cao Physics in Medicine & Biology 59 (17), 4945, 2014 | 24 | 2014 |
Joint B0 and image estimation integrated with model based reconstruction for field map update and distortion correction in prostate diffusion MRI M Usman, L Kakkar, A Matakos, A Kirkham, S Arridge, D Atkinson Magnetic resonance imaging 65, 90-99, 2020 | 13 | 2020 |
Joint estimation of image and fieldmap in parallel MRI using single-shot acquisitions A Matakos, JA Fessler 2010 IEEE International Symposium on Biomedical Imaging: From Nano to Macro …, 2010 | 13 | 2010 |
Method and apparatus for adaptive compressed sensing (CS) to correct motion artifacts in magnetic resonance imaging (MRI) AJ Wheaton, A Matakos US Patent 10,950,014, 2021 | 11 | 2021 |
Integration of multi-modality imaging for accurate 3D reconstruction of human coronary arteries in vivo GD Giannoglou, YS Chatzizisis, G Sianos, D Tsikaderis, A Matakos, ... Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2006 | 11 | 2006 |
A robust method for estimating B0 inhomogeneity field in the liver by mitigating fat signals and phase-wrapping A Matakos, JM Balter, Y Cao Tomography 3 (2), 79-88, 2017 | 10 | 2017 |
In vivo comparative study of linear versus geometrically correct three-dimensional reconstruction of coronary arteries YS Chatzizisis, GD Giannoglou, G Sianos, A Ziakas, D Tsikaderis, ... The American journal of cardiology 101 (2), 263-267, 2008 | 8 | 2008 |
Image restoration using non-circulant shift-invariant system models A Matakos, S Ramani, JA Fessler 2012 19th IEEE International Conference on Image Processing, 3061-3064, 2012 | 6 | 2012 |
Dynamic Image and Fieldmap Joint Estimation Methods for MRI Using Single-Shot Trajectories. A Matakos | 3 | 2013 |
Dynamic MR image and fieldmap joint reconstruction accounting for through-plane fieldmap gradients A Matakos, JA Fessler 2011 IEEE International Symposium on Biomedical Imaging: From Nano to Macro …, 2011 | 3 | 2011 |
Method and apparatus for automated regularization tuning in magnetic resonance imaging (MRI) using compressed sensing (CS) AJ Wheaton, A Matakos, SD Sharma US Patent 11,064,901, 2021 | 1 | 2021 |
WE‐G‐18C‐01: Novel Method for Geometrically Undistorted B0 Inhomogeneity Field Map Estimation and Image Correction A Matakos, J Balter, Y Cao Medical Physics 41 (6Part31), 528-528, 2014 | 1 | 2014 |
Method and apparatus for automated regularization tuning in magnetic resonance imaging (MRI) using compressed sensing (CS) AJ Wheaton, A Matakos, SD Sharma US Patent 11,389,077, 2022 | | 2022 |
Devices, systems, and methods for medical imaging AJ Wheaton, A Matakos US Patent 10,719,934, 2020 | | 2020 |
Model based joint B0 and image estimation framework for dynamic field mapping and signal pile-up correction in prostate diffusion MRI M Usman, A Matakos, L Kakkar, S Arridge, D Atkinson International Society for Magnetic Resonance in Medicine (ISMRM), 2019 | | 2019 |
TH‐A‐BRF‐10: Quantification of Subject‐Specific Susceptibility‐Related Geometric Distortion in Clinical Liver MRI for Radiation Therapy T Zhu, A Matakos, M Feng, T Lawrence, Y Cao Medical Physics 41 (6Part31), 538-539, 2014 | | 2014 |
OC-0084: Iterative correction of subject-dependent B0 inhomogeneity field maps for geometric distortion correction A Matakos, J Balter, Y Cao Radiotherapy and Oncology, S33-S34, 2014 | | 2014 |