Impact of temperature on surface charges accumulation on insulators in SF6-filled DC-GIL H Zhou, G Ma, C Li, C Shi, S Qin IEEE Transactions on Dielectrics and Electrical Insulation 24 (1), 601-610, 2017 | 107 | 2017 |
High sensitive and reliable fiber Bragg grating hydrogen sensor for fault detection of power transformer G Ma, C Li, Y Luo, R Mu, L Wang Sensors and Actuators B: Chemical 169, 195-198, 2012 | 106 | 2012 |
Distributed partial discharge detection in a power transformer based on phase-shifted FBG GM Ma, HY Zhou, C Shi, YB Li, Q Zhang, CR Li, Q Zheng IEEE Sensors Journal 18 (7), 2788-2795, 2018 | 97 | 2018 |
Optical fiber optofluidic bio‐chemical sensors: a review L Li, Y Zhang, Y Zhou, W Zheng, Y Sun, G Ma, Y Zhao Laser & photonics reviews 15 (7), 2000526, 2021 | 86 | 2021 |
Designing epoxy insulators in SF 6-filled DC-GIL with simulations of ionic conduction and surface charging G Ma, H Zhou, C Li, J Jiang, X Chen IEEE Transactions on Dielectrics and Electrical Insulation 22 (6), 3312-3320, 2015 | 83 | 2015 |
A fiber Bragg grating tension and tilt sensor applied to icing monitoring on overhead transmission lines G Ma, C Li, J Quan, J Jiang, Y Cheng IEEE Transactions on power delivery 26 (4), 2163-2170, 2011 | 76 | 2011 |
TDLAS-based detection of dissolved methane in power transformer oil and field application J Jiang, M Zhao, GM Ma, HT Song, CR Li, X Han, C Zhang IEEE Sensors Journal 18 (6), 2318-2325, 2018 | 73 | 2018 |
Optical sensors for power transformer monitoring: A review G Ma, Y Wang, W Qin, H Zhou, C Yan, J Jiang, Y Ju High Voltage 6 (3), 367-386, 2021 | 71 | 2021 |
Multi-gas detection in power transformer oil based on tunable diode laser absorption spectrum J Jiang, Z Wang, X Han, C Zhang, G Ma, C Li, Y Luo IEEE Transactions on Dielectrics and Electrical Insulation 26 (1), 153-161, 2019 | 69 | 2019 |
Highly sensitive dissolved hydrogen sensor based on side-polished fiber Bragg grating J Jiang, GM Ma, CR Li, HT Song, YT Luo, HB Wang IEEE Photonics Technology Letters 27 (13), 1453-1456, 2015 | 66 | 2015 |
Tracing acetylene dissolved in transformer oil by tunable diode laser absorption spectrum G Ma, S Zhao, J Jiang, H Song, C Li, Y Luo, H Wu Scientific reports 7 (1), 14961, 2017 | 64 | 2017 |
Fiber Bragg grating sensor for hydrogen detection in power transformers GM Ma, CR Li, RD Mu, J Jiang, YT Luo IEEE Transactions on Dielectrics and Electrical Insulation 21 (1), 380-385, 2014 | 63 | 2014 |
A high sensitivity optical fiber sensor for GIS partial discharge detection GM Ma, H Zhou, M Zhang, CR Li, Y Yin, YY Wu IEEE Sensors Journal 19 (20), 9235-9243, 2019 | 62 | 2019 |
Optical sensing in condition monitoring of gas insulated apparatus: A review H Zhou, G Ma, Y Wang, W Qin, J Jiang, C Yan, C Li High Voltage 4 (4), 259-270, 2019 | 60 | 2019 |
A passive optical fiber anemometer for wind speed measurement on high-voltage overhead transmission lines GM Ma, CR Li, J Jiang, JY Liang, YT Luo, YC Cheng IEEE Transactions on Instrumentation and Measurement 61 (2), 539-544, 2011 | 56 | 2011 |
A high sensitivity optical fiber interferometer sensor for acoustic emission detection of partial discharge in power transformer HY Zhou, GM Ma, M Zhang, HC Zhang, CR Li IEEE Sensors Journal 21 (1), 24-32, 2019 | 51 | 2019 |
A fiber Bragg grating-based dynamic tension detection system for overhead transmission line galloping G Ma, Y Li, N Mao, C Shi, B Zhang, C Li Sensors 18 (2), 365, 2018 | 50 | 2018 |
Review of flash sintering with strong electric field H Zhou, X Li, Y Zhu, J Liu, A Wu, G Ma, X Wang, Z Jia, L Wang High Voltage 7 (1), 1-11, 2022 | 46 | 2022 |
A wireless and passive online temperature monitoring system for GIS based on surface-acoustic-wave sensor GM Ma, Z Wu, HY Zhou, J Jiang, WX Chen, SS Zheng, CR Li, X Li, ... IEEE Transactions on Power Delivery 31 (3), 1270-1280, 2015 | 46 | 2015 |
Measurement of VFTO Based on the Transformer Bushing Sensor M Ma, L Li, Q Quan, J Jiang Power Delivery, IEEE Transactions on, 1-1, 2011 | 45 | 2011 |