Optimal design of a multi-story double skin facade J Joe, W Choi, Y Kwak, JH Huh Energy and Buildings 76, 143-150, 2014 | 104 | 2014 |
Operation and control strategies for multi-storey double skin facades during the heating season W Choi, J Joe, Y Kwak, JH Huh Energy and buildings 49, 454-465, 2012 | 95 | 2012 |
Optimization method for multiple heat source operation including ground source heat pump considering dynamic variation in ground temperature S Ikeda, W Choi, R Ooka Applied Energy 193, 466-478, 2017 | 88 | 2017 |
Effect of natural convection on thermal response test conducted in saturated porous formation: Comparison of gravel-backfilled and cement-grouted borehole heat exchangers W Choi, R Ooka Renewable Energy 96, 891-903, 2016 | 83 | 2016 |
Load characteristics and operation strategies of building integrated with multi-story double skin facade J Joe, W Choi, H Kwon, JH Huh Energy and buildings 60, 185-198, 2013 | 80 | 2013 |
Interpretation of disturbed data in thermal response tests using the infinite line source model and numerical parameter estimation method W Choi, R Ooka Applied Energy 148, 476-488, 2015 | 75 | 2015 |
Exergy analysis of a hybrid ground-source heat pump system K Menberg, Y Heo, W Choi, R Ooka, R Choudhary, M Shukuya Applied Energy 204, 31-46, 2017 | 71 | 2017 |
Bayesian inference for thermal response test parameter estimation and uncertainty assessment W Choi, H Kikumoto, R Choudhary, R Ooka Applied Energy 209, 306-321, 2018 | 65 | 2018 |
Impact of long-term operation of ground-source heat pump on subsurface thermal state in urban areas W Choi, R Ooka, Y Nam Sustainable cities and society 38, 429-439, 2018 | 61 | 2018 |
Model predictive control of building energy systems with thermal energy storage in response to occupancy variations and time-variant electricity prices D Lee, R Ooka, S Ikeda, W Choi, Y Kwak Energy and Buildings 225, 110291, 2020 | 49 | 2020 |
Effect of disturbance on thermal response test, part 2: Numerical study of applicability and limitation of infinite line source model for interpretation under disturbance from … W Choi, R Ooka Renewable Energy 85, 1090-1105, 2016 | 45 | 2016 |
Effect of disturbance on thermal response test, part 1: Development of disturbance analytical model, parametric study, and sensitivity analysis W Choi, R Ooka Renewable Energy 85, 306-318, 2016 | 33 | 2016 |
Exergy analysis for unsteady-state heat conduction W Choi, R Ooka, M Shukuya International Journal of Heat and Mass Transfer 116, 1124-1142, 2018 | 30 | 2018 |
Experimental analysis of artificial intelligence-based model predictive control for thermal energy storage under different cooling load conditions D Lee, R Ooka, Y Matsuda, S Ikeda, W Choi Sustainable Cities and Society 79, 103700, 2022 | 22 | 2022 |
Experimental and numerical investigation of energy saving potential of centralized and decentralized pumping systems M Liu, R Ooka, W Choi, S Ikeda Applied Energy 251, 113359, 2019 | 22 | 2019 |
New perspectives in thermal performance test: Cost-effective apparatus and extended data analysis W Choi, H Kikumoto, R Ooka Energy and Buildings 180, 109-121, 2018 | 19 | 2018 |
Bayesian inference of structural error in inverse models of thermal response tests W Choi, K Menberg, H Kikumoto, Y Heo, R Choudhary, R Ooka Applied Energy 228, 1473-1485, 2018 | 19 | 2018 |
Artificial neural network prediction models of stratified thermal energy storage system and borehole heat exchanger for model predictive control D Lee, R Ooka, S Ikeda, W Choi Science and Technology for the Built Environment 25 (5), 534-548, 2019 | 18 | 2019 |
Critical comparison between thermal performance test (TPT) and thermal response test (TRT): Differences in heat transfer process and extractable information W Choi, H Kikumoto, R Ooka Energy Conversion and Management 199, 111967, 2019 | 15 | 2019 |
Development of probabilistic assessment framework for pedestrian wind environment using Bayesian technique H Kikumoto, W Choi, R Ooka Building and Environment 187, 107419, 2021 | 13 | 2021 |