Laser ultrasonics detection of an embedded crack in a composite spherical particle A Amziane, M Amari, D Mounier, JM Breteau, N Joly, J Banchet, D Tisseur, ... Ultrasonics 52 (1), 39-46, 2012 | 37 | 2012 |
Scattering correction using continuously thickness-adapted kernels N Bhatia, D Tisseur, F Buyens, JM Létang NDT & E International 78, 52-60, 2016 | 26 | 2016 |
CIVA computed tomography modeling R Fernandez, SA Legoupil, M Costin, A Leveque proceedings of the World Conference of NDT, 2012 | 19 | 2012 |
Quality control of High Temperature Reactors (HTR) compacts via X-ray tomography D Tisseur, J Banchet, PG Duny, M Mahe, MP Vitali | 15 | 2006 |
CIVA CT, an advanced simulation platform for NDT M Costin, D Tisseur, C Vienne, R Guillamet, H Banjak, N Bhatia, ... 6th Conference on Industrial Computed Tomography, Wels, Austria, 2016 | 12 | 2016 |
Fast high-energy X-ray imaging for Severe Accidents experiments on the future PLINIUS-2 platform L Berge, N Estre, D Tisseur, E Payan, D Eck, V Bouyer, N Cassiaut-Louis, ... IEEE Transactions on Nuclear Science 65 (9), 2573-2581, 2018 | 11 | 2018 |
Measurement of cumulative photofission yields of 235U and 238U with a 16 MeV Bremsstrahlung photon beam M Delarue, E Simon, B Pérot, PG Allinei, N Estre, E Payan, D Eck, ... Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2021 | 9 | 2021 |
Performance evaluation of several well-known and new scintillators for MeV X-ray imaging D Tisseur, N Estre, L Tamagno, C Eleon, D Eck, E Payan, N Cherepy 2018 IEEE Nuclear Science Symposium and Medical Imaging Conference …, 2018 | 9 | 2018 |
Convolution-based scatter correction using kernels combining measurements and Monte Carlo simulations N Bhatia, D Tisseur, JM Létang Journal of X-ray science and technology 25 (4), 613-628, 2017 | 9 | 2017 |
Evaluation of a scattering correction method for high energy tomography D Tisseur, N Bhatia, N Estre, L Berge, D Eck, E Payan EPJ Web of Conferences 170, 06006, 2018 | 8 | 2018 |
Confidence map tool for gradient-based X-ray phase contrast imaging A Stolidi, G Giakoumakis, J Primot, A Jarnac, D Tisseur Optics Express 30 (3), 4302-4311, 2022 | 7 | 2022 |
Detector upgrade for fast MeV X-ray imaging for severe accidents experiments D Tisseur, D Eck, N Estre, M Kistler, E Payan, L Tamagno IEEE Transactions on Nuclear Science 67 (7), 1715-1721, 2020 | 7 | 2020 |
Localization of nuclear materials in large concrete radioactive waste packages using photofission delayed gamma rays M Delarue, E Simon, B Pérot, PG Allinei, N Estre, D Eck, E Payan, ... EPJ Web of Conferences 253, 08003, 2021 | 6 | 2021 |
Design of a very efficient detector for High Energy Tomography N Estre, D Eck, C Eleon, M Kistler, E Payan, L Tamagno, D Tisseur 2018 IEEE Nuclear Science Symposium and Medical Imaging Conference …, 2018 | 6 | 2018 |
Separable scatter model of the detector and object contributions using continuously thickness-adapted kernels in CBCT N Bhatia, D Tisseur, S Valton, JM Létang Journal of X-ray science and Technology 24 (5), 723-732, 2016 | 6 | 2016 |
Non-destructive characterization method, especially for characterizing particles of nuclear fuel for a high-temperature reactor J Banchet, D Tisseur US Patent 8,160,201, 2012 | 6 | 2012 |
RT Modelling for NDT Recent and Future Developments in the CIVA RT/CT Module R Fernandez, L Clement, D Tisseur, R Guillamet, M Costin, C Vienne, ... Proceedings of the 19th World Conference on Non-Destructive Testing (WCNDT …, 2016 | 5 | 2016 |
POD calculation on a radiographic weld inspection with CIVA 11 RT module D Tisseur, M Costin, S Fournier, C Reece, A Schumm 10th International Conference on NDE in Relation to Structural Integrity for …, 2013 | 5 | 2013 |
Laser ultrasonics evaluation and testing of coated HTR nuclear fuel A Amziane, M Amari, D Mounier, JM Breteau, N Joly, M Edely, M Larcher, ... Optical Measurement Systems for Industrial Inspection VII 8082, 652-661, 2011 | 5 | 2011 |
Phase contrast imaging in laboratory D Tisseur, JM Létang, J Banchet Proceedings of DIR, 25-27, 2007 | 5 | 2007 |