A mercury (II) selective sensor based on N, N′-bis (salicylaldehyde)-phenylenediamine as neutral carrier for potentiometric analysis in water samples HM Abu-Shawish Journal of Hazardous Materials 167 (1-3), 602-608, 2009 | 99 | 2009 |
Development of novel potentiometric sensors for determination of tartrazine dye concentration in foodstuff products HMA Shawish, NA Ghalwa, SM Saadeh, H El Harazeen Food chemistry 138 (1), 126-132, 2013 | 74 | 2013 |
Improving the detection limits of antispasmodic drugs electrodes by using modified membrane sensors with inner solid contact H Ibrahim, YM Issa, HM Abu-Shawish Journal of pharmaceutical and biomedical analysis 44 (1), 8-15, 2007 | 68 | 2007 |
A comparative study of solid and liquid inner contact benzalkonium chloride ion-selective electrode membranes HMA Shawish, AM Khedr, KI Abed-Almonem, M Gaber Talanta 101, 211-219, 2012 | 61 | 2012 |
New room temperature ionic liquids with interesting ecotoxicological and antimicrobial properties SM Saadeh, Z Yasseen, FA Sharif, HMA Shawish Ecotoxicology and environmental safety 72 (6), 1805-1809, 2009 | 60 | 2009 |
Potentiometric flow injection analysis of mebeverine hydrochloride in serum and urine H Ibrahim, YM Issa, HM Abu-Shawish Journal of pharmaceutical and biomedical analysis 36 (5), 1053-1061, 2005 | 59 | 2005 |
Enhanced sensitivity for Cu (II) by a salicylidine-functionalized polysiloxane carbon paste electrode HM Abu-Shawish, SM Saadeh, AR Hussien Talanta 76 (4), 941-948, 2008 | 52 | 2008 |
Improved determination of tramadol hydrochloride in biological fluids and pharmaceutical preparations utilizing a modified carbon paste electrode HM Abu-Shawish, NA Ghalwa, FR Zaggout, SM Saadeh, AR Al-Dalou, ... Biochemical Engineering Journal 48 (2), 237-245, 2010 | 51 | 2010 |
Determination of benzalkonium chloride preservative in pharmaceutical formulation of eye and ear drops using new potentiometric sensors M Gaber, HMA Shawish, AM Khedr, KI Abed-Almonem Materials Science and Engineering: C 32 (8), 2299-2305, 2012 | 46 | 2012 |
Determination of haloperidol drug in ampoules and in urine samples using a potentiometric modified carbon paste electrode HMA Shawish, KIA Almonem, SM Saadeh, WS Al-lham Measurement 78, 180-186, 2016 | 45 | 2016 |
Potentiometric Response of Modified Carbon Paste Electrode Based on Mixed Ion‐Exchangers HM Abu‐Shawish Electroanalysis: An International Journal Devoted to Fundamental and …, 2008 | 45 | 2008 |
Determination of Trihexyphenidyl hydrochloride drug in tablets and urine using a potentiometric carbon paste electrode HMA Shawish, M Elhabiby, HSA Aziz, SM Saadeh, A Tbaza Sensors and Actuators B: Chemical 235, 18-26, 2016 | 44 | 2016 |
Optimization of tramadol–PVC membrane electrodes using miscellaneous plasticizers and ion-pair complexes HMA Shawish, SM Saadeh, AR Al-Dalou, NA Ghalwa, AA Abou Assi Materials Science and Engineering: C 31 (2), 300-306, 2011 | 41 | 2011 |
Potentiometric flow injection analysis of dicyclomine hydrochloride in serum, urine and milk H Ibrahim, YM Issa, HM Abu-Shawish Analytica chimica acta 532 (1), 79-88, 2005 | 39 | 2005 |
A new potentiometric sensor for the determination of ketamine hydrochloride in ampoules and urine HMA Shawish, SM Saadeh, H Tamos, KI Abed-Almonem Analytical Methods 7 (1), 301-308, 2015 | 38* | 2015 |
Modified carbon paste electrode for potentiometric determination of silver (I) ions in burning cream and radiological films HM Abu-Shawish, SM Saadeh, HM Dalloul, B Najri, H Al Athamna Sensors and Actuators B: Chemical 182, 374-381, 2013 | 38 | 2013 |
Carbon paste electrode for the potentiometric flow injection analysis of drotaverine hydrochloride in serum and urine YM Issa, H Ibrahim, HM Abu-Shawish Microchimica Acta 150, 47-54, 2005 | 36 | 2005 |
Modified carbon paste electrode for potentiometric determination of diquat dibromide pesticide in water and urine samples HMA Shawish, NA Ghalwa, M Hamada, AH Basheer Materials Science and Engineering: C 32 (2), 140-145, 2012 | 35 | 2012 |
Lead (II) complexes with some SNO and ONO tridentate Schiff base ligands and their evaluation as lead (II) sensors SM Saadeh, HMA Shawish, HM Dalloul, NM El-Halabi, BK Daher Materials Science and Engineering: C 32 (3), 619-624, 2012 | 34 | 2012 |
A New chemically modified carbon paste electrode for determination of copper based on n, n′-disalicylidenehexameythylenediaminate copper (ii) complex HM Abu-Shawish, SM Saadeh Sensor Letters 5 (3-4), 565-571, 2007 | 32 | 2007 |