Treatment of Contact Dermatitis Associated With Spinal Cord Stimulator Pulse Generator

N Gadgil, AW Burton, A Viswanathan - Neuromodulation: Technology at the …, 2013 - Elsevier
Background Expanded polytetrafluoroethylene sheets have been successfully used as a
biologic barrier in the treatment of pacemaker contact dermatitis. Technique In this report, we …

Pacemaker contact dermatitis: the effective use of a polytetrafluoroethylene sheet

K Ishii, E Kodani, S Miyamoto, T Otsuka… - Pacing and clinical …, 2006 - Wiley Online Library
A 52‐year‐old man with Down's syndrome was implanted with a DDDR pacemaker for
advanced atrioventricular block. He was admitted with development of skin eczema and …

Methacrylate sensitivity and transcutaneous electrical nerve stimulation (TENS).

P Marren, D De Berker… - Contact Dermatitis …, 1991 - search.ebscohost.com
The article reports about dermatitis caused by transcutaneous electrical nerve stimulation
(TENS), recommended for pain relief. A 35-year old nurse applied TENS for back pain. After …

Allergic reaction to peripheral nerve stimulator

L Zhou, A Lee, R Schaffner… - The Open Neurosurgery …, 2012 - benthamopen.com
Objective: Pain physicians should be aware of a rare but possible complication associated
with the use of pe-ripheral nerve stimulation. While pacemaker dermatitis and allergic …

Detailed analysis of allergic cutaneous reactions to spinal cord stimulator devices

ZA Chaudhry, U Najib, ZH Bajwa… - Journal of Pain …, 2013 - Taylor & Francis
The use of spinal cord stimulation (SCS) devices to treat chronic, refractory neuropathic pain
continues to expand in application. While device-related complications have been well …

[PDF][PDF] Allergic contact dermatitis caused by acrylic acid used in transcutaneous electrical nervous stimulation

D Dittmar, J Dahlin, C Persson, ML Schuttelaar - Contact Dermatitis, 2017 - research.rug.nl
Transcutaneous electrical nervous stimulation (TENS) is an effective therapy for chronic
lower back pain, and has few side effects as compared with pharmacological treatment (1 …

Generator and/or lead extrusion

J Rabi, M Anitescu - Challenging Cases and Complication Management in …, 2018 - Springer
Implantable pulse generator (IPG) or lead extrusion is a rare phenomenon in which the
battery or leads of the spinal cord stimulator (SCS) system protrudes through the skin. The …

[HTML][HTML] Contact dermatitis following an intensive transcranial direct current stimulation protocol for major depressive disorder

JP Miron, M Couture, VD Jodoin… - … Clinical Research in …, 2023 - brainstimjrnl.com
Transcranial direct current stimulation (tDCS) is being investigated for several
neuropsychiatric conditions, including major depressive disorder (MDD)[1–3]. Common side …

[引用][C] Contact dermatitis after transcranial direct current stimulation

P Riedel, S Kabisch, P Ragert… - Brain Stimulation: Basic …, 2012 - brainstimjrnl.com
3. Prikryl R, Kasparek T, Skotakova S, Ustohal L, Kucerova H, Ceskova E. Treatment of
negative symptoms of schizophrenia using repetitive transcranial magnetic stimulation in a …

Long-term results of a cardiovascular implantable electronic device wrapped with an expanded polytetrafluoroethylene sheet

B Yashiro, M Shoda, Y Tomizawa, T Manaka… - Journal of Artificial …, 2012 - Springer
The use of an expanded polytetrafluoroethylene (ePTFE) sheet wrapping device for patients
with pacemaker contact dermatitis is still controversial. This study aimed to retrospectively …