T1 mapping for myocardial extracellular volume measurement by CMR: bolus only versus primed infusion technique
SK White, DM Sado, M Fontana, SM Banypersad… - JACC: Cardiovascular …, 2013 - jacc.org
Objectives: The aim of this study was to determine the accuracy of the contrast “bolus only”
T1 mapping cardiac magnetic resonance (CMR) technique for measuring myocardial …
T1 mapping cardiac magnetic resonance (CMR) technique for measuring myocardial …
T1 measurements in the human myocardium: The effects of magnetization transfer on the SASHA and MOLLI sequences
MD Robson, SK Piechnik… - Magnetic resonance …, 2013 - Wiley Online Library
Purpose Quantitative mapping of the native T1 of the heart using the modified look‐locker
inversion recovery (MOLLI) technique provides high quality diagnostic information without …
inversion recovery (MOLLI) technique provides high quality diagnostic information without …
[HTML][HTML] T2 quantification for improved detection of myocardial edema
S Giri, YC Chung, A Merchant, G Mihai… - Journal of …, 2009 - Elsevier
Abstract Background T2-Weighted (T2W) magnetic resonance imaging (MRI) pulse
sequences have been used to detect edema in patients with acute myocardial infarction and …
sequences have been used to detect edema in patients with acute myocardial infarction and …
[HTML][HTML] Saturation pulse design for quantitative myocardial T1 mapping
K Chow, P Kellman, BS Spottiswoode… - Journal of …, 2015 - Elsevier
Background Quantitative saturation-recovery based T 1 mapping sequences are less
sensitive to systematic errors than the Modified Look-Locker Inversion recovery (MOLLI) …
sensitive to systematic errors than the Modified Look-Locker Inversion recovery (MOLLI) …
Cardiac chamber quantification using magnetic resonance imaging at 7 Tesla—a pilot study
F von Knobelsdorff-Brenkenhoff, T Frauenrath… - European …, 2010 - Springer
Objectives Interest in cardiovascular magnetic resonance (CMR) at 7 T is motivated by the
expected increase in spatial and temporal resolution, but the method is technically …
expected increase in spatial and temporal resolution, but the method is technically …
Simultaneous T1, T2, and T1ρ cardiac magnetic resonance fingerprinting for contrast agent–free myocardial tissue characterization
Purpose To develop a simultaneous T1, T2, and T1ρ cardiac magnetic resonance
fingerprinting (MRF) approach to enable comprehensive contrast agent–free myocardial …
fingerprinting (MRF) approach to enable comprehensive contrast agent–free myocardial …
Joint myocardial T1 and T2 mapping using a combination of saturation recovery and T2‐preparation
Purpose To develop a heart‐rate independent breath‐held joint T1–T2 mapping sequence
for accurate simultaneous estimation of coregistered myocardial T1 and T2 maps. Methods …
for accurate simultaneous estimation of coregistered myocardial T1 and T2 maps. Methods …
Myocardial T1 Values at 1.5 T: Normal Values for General Electric Scanners and Sex‐Related Differences
Background No data are available about normal ranges for native T1 in human myocardium
using General Electric (GE) scanners. Purpose To establish normal ranges for myocardial …
using General Electric (GE) scanners. Purpose To establish normal ranges for myocardial …
[HTML][HTML] Optimized saturation recovery protocols for T1-mapping in the heart: influence of sampling strategies on precision
Background T1-mapping has the potential to detect and quantify diffuse processes such as
interstitial fibrosis. Detection of disease at an early stage by measurement of subtle changes …
interstitial fibrosis. Detection of disease at an early stage by measurement of subtle changes …
[HTML][HTML] Standardization of T1-mapping in cardiovascular magnetic resonance using clustered structuring for benchmarking normal ranges
Background Cardiovascular magnetic resonance T1-mapping is increasingly used for tissue
characterization, commonly based on Modified Look-Locker Inversion recovery (MOLLI) …
characterization, commonly based on Modified Look-Locker Inversion recovery (MOLLI) …