A californium-252 fission spectrum irradiation facility for neutron reaction rate measurements
JA Grundl, V Spiegel, CM Eisenhauer… - Nuclear …, 1977 - Taylor & Francis
Spontaneous fission sources of 252Cf, lightly encapsulated and with neutron source
strengths approaching 1010 n/s, have been developed especially for integral cross-section …
strengths approaching 1010 n/s, have been developed especially for integral cross-section …
Neutron sources for standard-based testing
R Radev, T McLean - 2014 - osti.gov
The DHS TC Standards and the consensus ANSI Standards use 252Cf as the neutron
source for performance testing because its energy spectrum is similar to the 235U and …
source for performance testing because its energy spectrum is similar to the 235U and …
Establishment of a simple neutron calibration field using a moderated 252Cf source: Part II. Experimental characterization of simple neutron calibration field
S Iwai, T Ohkubo, A Hara, T Nakamura - Nuclear Instruments and Methods …, 1987 - Elsevier
This paper describes the development and experimental standardization of neutron fields
simply arranged for detector calibrations used for radiation control and environmental …
simply arranged for detector calibrations used for radiation control and environmental …
252Cf: the potential for activation analysis of selected medium-weight and heavy elements in the limited neutron flux of a partially depleted 50 μg source
AE Pillay - Applied Radiation and Isotopes, 2002 - Elsevier
A 50μg 252Cf source, depleted by about 2 orders of magnitude from its original neutron
output, was used to examine the sensitivity of neutron activation analysis for a selection of …
output, was used to examine the sensitivity of neutron activation analysis for a selection of …
Low-energy neutron spectrometer and its application for 252Cf neutron spectrum measurements
A Lajtai, PP Dyachenko, VN Kononov… - Nuclear Instruments and …, 1990 - Elsevier
A time-of-flight spectrometer with a relatively thick 6 Li glass scintillator for neutron detection
and an ionization chamber containing minimal built-in material for fission fragment detection …
and an ionization chamber containing minimal built-in material for fission fragment detection …
Electronic Assay of Californium-252 Neutron Sources
TR Herold - Nuclear Technology, 1972 - Taylor & Francis
A new electronic method has been developed that requires about 10 min to assay 252Cf
sources between 1 μg and 50 mg. The assay is made by placing the 252Cf source in the …
sources between 1 μg and 50 mg. The assay is made by placing the 252Cf source in the …
A Review of High Intensity Neutron Sources and Their Application in Industry
G Olive, JF Cameron, CG Clayton - 1962 - osti.gov
Clayton (United Kingdom Atomic Energy Authority. ReVarious high intensity neutron sources
which are now available are reviewed and their present and future applications in industry …
which are now available are reviewed and their present and future applications in industry …
Neutron and gamma-ray spectra of 239PuBe and 241AmBe
HR Vega-Carrillo, E Manzanares-Acuña… - Applied Radiation and …, 2002 - Elsevier
Neutron and gamma-ray spectra of 239PuBe and 241AmBe were measured and their
dosimetric features were calculated. Neutron spectra were measured using a multisphere …