[HTML][HTML] A comparison of untagged gamma-ray and tagged-neutron yields from 241AmBe and 238PuBe sources

J Scherzinger, R Al Jebali, JRM Annand… - Applied Radiation and …, 2017 - Elsevier
Untagged gamma-ray and tagged-neutron yields from 241 AmBe and 238 PuBe mixed-field
sources have been measured. Gamma-ray spectroscopy measurements from 1 to 5 MeV …

[HTML][HTML] Spectrometers for compact neutron sources

J Voigt, S Böhm, JP Dabruck, U Rücker… - Nuclear Instruments and …, 2018 - Elsevier
We discuss the potential for neutron spectrometers at novel accelerator driven compact
neutron sources. Such a High Brilliance Source (HBS) relies on low energy nuclear …

[HTML][HTML] The evaluation of 235U (n, f) above 100 keV for ENDF/BV and the implications of a unified 235U mass scale

WP Poenitz, JW Meadows… - Proc. Int. Conf. on Nuclear …, 1980 - books.google.com
A previously reported evaluation of 235U (n, f) in the fast neutron energy range was updated
to include data published up to the 1978 Harwell Conference on Neutron Physics. The …

Neutron sources in North America: Present and future

T Holden, AD Krawitz, I Anderson - JOM, 2006 - Springer
Six neutron sources are available for research in North America. The facilities are funded by
their respective governments as user-facilities. User proposals are accepted on a regular …

[图书][B] Safeguards Applications for Isotopic Neutron Sources

JR Beyster, L Kull - 1970 - books.google.com
Isotope radiation sources are an appealing alternative to accelerator sources because of
their relative simplicity and reliably predictable performance. However, their use also …

Nuclear design parameters for a monoenergetic neutron source

RL Lehman - The International Journal of Applied Radiation and …, 1968 - Elsevier
The nuclear design parameters in the construction of a monoenergetic laboratory neutron
source have been evaluated. The most promising reaction was 13 C (α, n) 16 0, employing …

Improvement in the practical implementation of neutron source strength calibration using prompt gamma rays

R Khabaz, HR Vega-Carrillo - Applied Radiation and Isotopes, 2013 - Elsevier
In this study, the neutron emission rate from neutron sources using prompt gamma rays in
hydrogen was determined, and several improvements were applied. Using Monte Carlo …

The US advanced neutron source

CD West - 1988 - osti.gov
The Advanced Neutron Source (ANS) is to be a new user experimental facility for all fields of
neutron research. The most important scientific justification for the ANS Project is to provide …

In-depth evaluation of 252Cf absolute calibration by passive neutron correlation counting method

D Henzlova, A Favalli, S Croft - Metrologia, 2019 - iopscience.iop.org
Abstract 252 Cf neutron sources are particularly convenient, and therefore widely used, to
characterize and calibrate many kinds of neutron detectors for both scientific and …

[图书][B] Neutron emission measurements from actinide waste isotopes

HH Saleh - 1995 - search.proquest.com
In this study, experiments were designed and performed to determine $\nu $ for U-235, Np-
237 and Am-243 in a fast neutron spectrum. Neutron emission measurements were …