Hemolytic anemia caused by aortic flap and inversion of felt strip after ascending aorta replacement
M Sakaguchi, T Takano - Journal of Cardiothoracic Surgery, 2016 - Springer
… of the proximal inner felt strip was the cause of severe hemolysis, we describe … hemolytic
anemia at the site of aortic flap and inverted felt strip after replacement of the ascending aorta…
anemia at the site of aortic flap and inverted felt strip after replacement of the ascending aorta…
Hemolytic Anemia soon after Replacement of Ascending Aorta for acute Aortic Dissection
I Shibasaki, H Fukuda, Y Yamada… - Dokkyo journal of …, 2015 - dmu.repo.nii.ac.jp
… )or jet of blood striking an inner felt strip4~7). We report a case of hemolytic anemia caused
by the inverted felt strip at the site after surgical treatment for aortic dissection using felt strips. …
by the inverted felt strip at the site after surgical treatment for aortic dissection using felt strips. …
Postoperative early hemolytic anemia due to inverted teflon felt strip after emergency repair for type A dissection
M Hata, I Yoshitake, S Wakui… - The Thoracic and …, 2012 - thieme-connect.com
… case complicated by hemolytic anemia due to an inverted Teflon felt strip without any
extra vascular factors after emergency graft replacement for type A acute aortic dissection (AAD). …
extra vascular factors after emergency graft replacement for type A acute aortic dissection (AAD). …
[PDF][PDF] A surgical case for hemolytic anemia after ascending and total arch replacement
Y Shingu, H Aoki, N Ebuoka, K Eya… - Annals of thoracic …, 2005 - researchgate.net
… replacement for DeBakey I type acute aortic dissection. The … of hemolytic anemia at the
site of inverted felt strip after total … A thrill was felt at the ascending aorta. The proximal …
site of inverted felt strip after total … A thrill was felt at the ascending aorta. The proximal …
… of three-dimensional transesophageal echocardiography for diagnosis of hemolytic anemia due to inverted internal felt strip after surgery for aortic dissection
T Oda, H Yasunaga, Y Zaima, A Arimura, S Imai… - Journal of Medical …, 2017 - Springer
… aortic stump fixation for AD is extremely rare. A 70-year-old woman underwent ascending
aorta replacement … , and the inverted internal felt strip was replaced with a bovine pericardial …
aorta replacement … , and the inverted internal felt strip was replaced with a bovine pericardial …
Haemolytic anaemia resulting from the surgical repair of acute type A aortic dissection
Y Sekine, S Yamamoto, T Fujikawa… - … and thoracic surgery, 2014 - academic.oup.com
… months later, we performed descending thoracic aortic replacement. We … We removed the
felt strip and performed proximal … In conclusion, haemolytic anaemia caused by an inverted …
felt strip and performed proximal … In conclusion, haemolytic anaemia caused by an inverted …
[HTML][HTML] Hemolytic anemia case caused by an inverted inner felt after Bentall operation
H Kang, JW Choe, DY Cho, DS Sohn… - Journal of Korean …, 2013 - ncbi.nlm.nih.gov
… the inner felt at the distal anastomosis was inverted causing a … of hemolytic anemia caused
by an inverted inner felt after … acute aortic dissection, reinforcing the aorta with a felt strip is …
by an inverted inner felt after … acute aortic dissection, reinforcing the aorta with a felt strip is …
Hemolysis following wrap aortoplasty for Type A aortic dissection repair: case report and review of the literature
MA Davison, DM Norton, AM Popoff… - Vascular …, 2018 - journals.sagepub.com
… largely attributed to the inversion of Teflon strips; however, … , hemolysis after Type A aortic
dissection repair occurs in a … stenosis related to inversion of a segment of felt. Some authors …
dissection repair occurs in a … stenosis related to inversion of a segment of felt. Some authors …
Aortic stenosis caused by the felt strip used in repair for acute aortic dissection
K Matsuura, H Ogino, K Minatoya… - … and Thoracic Surgery, 2004 - academic.oup.com
… ascending aorta to total arch replacement … hemolytic anemia due to stenosis of the proximal
anastomosis originating from a stiffened inner felt strip after repair for acute aortic dissection…
anastomosis originating from a stiffened inner felt strip after repair for acute aortic dissection…
… of Point-of-Care Transesophageal Echocardiography in the Intensive Care Unit for Detecting the Cause of Hemolytic Anemia After Ascending Aorta Replacement
Y Oshima, Y Seino, S Takagi, M Yamamoto… - … of Cardiothoracic and …, 2021 - Elsevier
… Most commonly, hemolysis after type A aortic dissection repair occurs in a delayed fashion,
… , hemolysis after ascending aortic replacement can occur due to inversion of Teflon felt strips …
… , hemolysis after ascending aortic replacement can occur due to inversion of Teflon felt strips …