Performance of a 3-bladed propeller pump to provide cavopulmonary assist in the failing Fontan circulation

AL Throckmorton, KK Ballman, CD Myers… - The Annals of thoracic …, 2008 - Elsevier
… that a propeller pump design would function optimally to provide cavopulmonary assist in a
univentricular Fontan … Although we have successfully used micro-axial flow pumps to provide

Development of a Mechanical Cavopulmonary Assist Device for the Failing Fontan Patients

J Kapadia - 2009 - scholarscompass.vcu.edu
… 5 have been successfully developed to augment the blood … 3-bladed impeller also
outperformed the 3-bladed impeller … the hydraulic performance of an infant and adult blood pump

[HTML][HTML] Cavopulmonary assist for the univentricular Fontan circulation: von Karman viscous impeller pump

MD Rodefeld, B Coats, T Fisher, GA Giridharan… - The Journal of thoracic …, 2010 - Elsevier
… for a viscous impeller pump to provide cavopulmonary assist. … performance and flow conditions
of a viscous impeller pump (… late after repair for support of “failing Fontan” physiology in …

Fontan circulatory assist device

CS Jhun, R Newswanger… - Journal of …, 2015 - asmedigitalcollection.asme.org
… to provide mechanical cavopulmonary support for failing … heart assist continuous flow
pump called the FCAD for failing … The FCAD showed promising performance in terms of …

Dual-propeller cavopulmonary pump for assisting patients with hypoplastic right ventricle

JN Jagani, A Untaroiu, AD Kalaria - ASAIO Journal, 2019 - journals.lww.com
fail to provide the pressure augmentation required to pump … axial flow cavopulmonary assist
device for Fontan patients within … hemodynamic performance and pump support would make

Chronic in vivo test of a right heart replacement blood pump for failed Fontan circulation

J Cysyk, JB Clark, R Newswanger, CS Jhun, J Izer… - ASAIO …, 2019 - journals.lww.com
support for patients who have failing Fontan circulation. The objective of this study was to
evaluate the pump in … performance curve (Figure 3B). The power consumption during the study (…

Development of Mechanical Cardiovascular Assist Devices for Fontan Patients: Two Novel Approaches

S Bhavsar - 2010 - scholarscompass.vcu.edu
… , expandable propeller blood pump as a cavopulmonary assist … measuring hydraulic
performance, the pump prototype was … axial flow blood pump having only a 3-bladed impeller, and …

A numerical simulation comparing a cavopulmonary assist device and VA ECMO for failing Fontan support

PL Hsu, D Wang, C Ballard-Croft, D Xiao… - ASAIO …, 2017 - journals.lww.com
… likely have different impacts on the failing Fontan circulation. … /VA ECMO pumping flow rate
on the failing Fontan circulation. … performance of the CPAD DLC is up to 4.5 L/min pumping

Development, Optimization, and Twisted Adjustment of an Axial Flow Blood Pump for Fontan Patients

M Sciolino - 2012 - scholarscompass.vcu.edu
… the design of a cavopulmonary assist device as a bridge-to-… A fixed-bladed impeller and
diffuser for this pump was … in pump performance through optimization of the impeller and diffuser …

[HTML][HTML] In vitro validation of a self-driving aortic-turbine venous-assist device for Fontan patients

K Pekkan, IB Aka, E Tutsak, E Ermek, H Balim… - The Journal of thoracic …, 2018 - Elsevier
efficiency is desired. For the venous side a mixed-impeller is found to be optimal to assist
the Fontan … -outlet venous pump configuration without a total cavopulmonary connection (TCPC…