Oxaliplatin pharmacokinetics and pharmacodynamics in adult cancer patients with impaired renal function

CH Takimoto, MA Graham, G Lockwood, CM Ng… - Clinical cancer …, 2007 - AACR
CH Takimoto, MA Graham, G Lockwood, CM Ng, A Goetz, D Greenslade, SC Remick…
Clinical cancer research, 2007AACR
Purpose: To characterize the pharmacokinetics and pharmacodynamics of oxaliplatin in
cancer patients with impaired renal function. Experimental Design: Thirty-four patients were
stratified by 24-h urinary creatinine clearance (CrCL) into four renal dysfunction groups:
group A (control, CrCL,≥ 60 mL/min), B (mild, CrCL, 40-59 mL/min), C (moderate, CrCL, 20-
39 mL/min), and D (severe, CrCL,< 20 mL/min). Patients were treated with 60 to 130 mg/m2
oxaliplatin infused over 2 h every 3 weeks. Pharmacokinetic monitoring of platinum in …
Abstract
Purpose: To characterize the pharmacokinetics and pharmacodynamics of oxaliplatin in cancer patients with impaired renal function.
Experimental Design: Thirty-four patients were stratified by 24-h urinary creatinine clearance (CrCL) into four renal dysfunction groups: group A (control, CrCL, ≥60 mL/min), B (mild, CrCL, 40-59 mL/min), C (moderate, CrCL, 20-39 mL/min), and D (severe, CrCL, <20 mL/min). Patients were treated with 60 to 130 mg/m2 oxaliplatin infused over 2 h every 3 weeks. Pharmacokinetic monitoring of platinum in plasma, plasma ultrafiltrates, and urine was done during cycles 1 and 2.
Results: Plasma ultrafiltrate platinum clearance strongly correlated with CrCL (r2 = 0.712). Platinum elimination from plasma was triphasic, and maximal platinum concentrations (Cmax) were consistent across all renal impairment groups. However, only the β-half-life was significantly prolonged by renal impairment, with values of 14.0 ± 4.3, 20.3 ± 17.7, 29.2 ± 29.6, and 68.1 h in groups A, B, C, and D, respectively (P = 0.002). At a dose level of 130 mg/m2, the area under the concentration time curve increased in with the degree of renal impairment, with values of 16.4 ± 5.03, 39.7 ± 11.5, and 44.6 ± 14.6 μg·h/mL, in groups A, B, and C, respectively. However, there was no increase in pharmacodynamic drug-related toxicities. Estimated CrCL using the Cockcroft-Gault method approximated the measured 24-h urinary CrCL (mean prediction error, −5.0 mL/min).
Conclusions: Oxaliplatin pharmacokinetics are altered in patients with renal impairment, but a corresponding increase in oxaliplatin-related toxicities is not observed.
AACR
以上显示的是最相近的搜索结果。 查看全部搜索结果