[PDF][PDF] Simultaneous heart rate-motion sensor technique to estimate energy expenditure

SJ Strath, DR Bassett, AM Swartz… - Medicine & Science in …, 2001 - Citeseer
SJ Strath, DR Bassett, AM Swartz, DL Thompson
Medicine & Science in Sports & Exercise, 2001Citeseer
ABSTRACT STRATH, SJ, DR BASSETT, JR., AM SWARTZ, and DL THOMPSON.
Simultaneous heart rate-motion sensor technique to estimate energy expenditure. Med. Sci.
Sports Exerc., Vol. 33, No. 12, 2001, pp. 2118–2123. Purpose: Heart rate (HR) and motion
sensors represent promising tools for physical activity (PA) assessment, as each provides an
estimate of energy expenditure (EE). Although each has inherent limitations, the
simultaneous use of HR and motion sensors may increase the accuracy of EE estimates …
Abstract
STRATH, SJ, DR BASSETT, JR., AM SWARTZ, and DL THOMPSON. Simultaneous heart rate-motion sensor technique to estimate energy expenditure. Med. Sci. Sports Exerc., Vol. 33, No. 12, 2001, pp. 2118–2123.
Purpose
Heart rate (HR) and motion sensors represent promising tools for physical activity (PA) assessment, as each provides an estimate of energy expenditure (EE). Although each has inherent limitations, the simultaneous use of HR and motion sensors may increase the accuracy of EE estimates. The primary purpose of this study was to establish the accuracy of predicting EE from the simultaneous HR-motion sensor technique. In addition, the accuracy of EE estimated by the simultaneous HR-motion sensor technique was compared to that of HR and motion sensors used independently.
Methods
Thirty participants (16 men: age, 33.1 12.2 yr; BMI, 26.1 0.7 kg· m 2; and 14 women: age, 31.9 13.1 yr; BMI, 27.2 1.1 kg· m 2 (mean SD)) performed arm and leg work in the laboratory for the purpose of developing individualized HR-VO2 regression equations. Participants then performed physical tasks in a field setting for 15 min each. CSA accelerometers placed on the arm and leg were to discriminate between upper and lower body movement, and HR was then used to predict EE (METs) from the corresponding arm or leg laboratory regression equation. A hip-mounted CSA accelerometer and Yamax pedometer were also used to predict EE. Predicted values (METs) were compared to measured values (METs), obtained via a portable metabolic measurement system (Cosmed K4b2).
Results
The Yamax pedometer and the CSA accelerometer on the hip significantly underestimated the energy cost of selected physical activities, whereas HR alone significantly overestimated the energy cost of selected physical activities. The simultaneous HR-motion sensor technique showed the strongest relationship with VO2 (R2 0.81) and did not significantly over-or underpredict the energy cost (P 0.341).
Conclusion
The simultaneous HR-motion sensor technique is a good predictor of EE during selected lifestyle activities, and allows researchers to more accurately quantify free-living PA. Key Words: PHYSICAL ACTIVITY, OXYGEN UPTAKE, EXERCISE, PEDOMETER, ACCELEROMETER
Citeseer
以上显示的是最相近的搜索结果。 查看全部搜索结果