Analytical evaluation of i-STAT portable clinical analyzer and use by nonlaboratory health-care professionals
E Jacobs, E Vadasdi, L Sarkozi, N Colman - Clinical Chemistry, 1993 - academic.oup.com
We evaluated the performance of the i-STAT Portable Clinical Analyzer, a hand-held
instrument that, with its current cartridge, analyzes for electrolytes, urea nitrogen, glucose …
instrument that, with its current cartridge, analyzes for electrolytes, urea nitrogen, glucose …
Direct potentiometric determination of sodium ion in blood. I. Potentiometric response in simple sodium chloride solutions.
P Bijster, KL Vink - Clinical chemistry, 1984 - academic.oup.com
We measured the emf of NaCl solutions (120-160 mmol/L) with a home-built cell in steady-
state and with some commercial direct potentiometric analyzers about 20 s after the sample …
state and with some commercial direct potentiometric analyzers about 20 s after the sample …
Direct potentiometric determination of sodium ion in blood. II. Influence of cations.
P Bijster, KL Vink - Clinical chemistry, 1984 - academic.oup.com
We measured the emf of NaCl solutions (120-160 mmol/L), with and without the addition of
KCl (5-20 mmol/L), CaCl2 (2-8 mmol/L), or MgCl2 (1-4 mmol/L). Measurements were made …
KCl (5-20 mmol/L), CaCl2 (2-8 mmol/L), or MgCl2 (1-4 mmol/L). Measurements were made …
Preanalytical variables in measurement of free (ionized) calcium in lithium heparin-containing blood collection tubes
DM Haverstick, LB Brill II, MG Scott, DE Bruns - Clinica Chimica Acta, 2009 - Elsevier
BACKGROUND: Measurements of free (ionized) calcium (iCa) are increasingly requested in
patient care locations where immediate analysis is unavailable. Evacuated blood collection …
patient care locations where immediate analysis is unavailable. Evacuated blood collection …
[引用][C] The apparent suppression of Na/K data obtained with ion-selective electrodes is due to junction potential and activity coefficient effects, not bicarbonate binding.
JD Czaban, AD Cormier, KD Legg - Clinical chemistry, 1982 - academic.oup.com
Biomedical, Newton, MA) ion-selective electrode type of analyzer relative to that obtained
with flame photometry. They were concerned because their results were in disagreement …
with flame photometry. They were concerned because their results were in disagreement …
DuPont aca III performance as tested according to NCCLS guidelines.
CC Garber, JO Westgard, L Milz, FC Larson - Clinical chemistry, 1979 - academic.oup.com
We evaluated the analytical performance of 10 representative channels on the new
microprocessor-controlled DuPont aca III according to the guidelines (draft documents PSEP …
microprocessor-controlled DuPont aca III according to the guidelines (draft documents PSEP …
[PDF][PDF] A study on effect of lipemia on electrolyte measurement by direct ion selective electrode method
Background: Lipemia affects electrolyte concentration obtained by indirect ion selective
electrode (ISE) method, but the specific influence on measurements by direct ion selective …
electrode (ISE) method, but the specific influence on measurements by direct ion selective …
Ionized calcium: whole blood, plasma or serum?
J Krahn, H Lou - Clinical Laboratory, 2008 - europepmc.org
Objectives To determine an optimal specimen type to be used for measurements of ionized
calcium (iCa) so that it applies properly to the reference interval. Also to determine the …
calcium (iCa) so that it applies properly to the reference interval. Also to determine the …
[HTML][HTML] Are sodium and potassium results on arterial blood gas analyzer equivalent to those on electrolyte analyzer?
S Gupta, AK Gupta, K Singh… - Indian journal of critical …, 2016 - ncbi.nlm.nih.gov
Objectives: The present study was conducted with the aim to compare the sodium (Na) and
potassium (K) results on arterial blood gas (ABG) and electrolyte analyzers both of which …
potassium (K) results on arterial blood gas (ABG) and electrolyte analyzers both of which …
Anion gap reference intervals show instrument dependence and weak correlation with albumin levels
B Pratumvinit, L Lam, N Kongruttanachok… - Clinica Chimica …, 2020 - Elsevier
Background Anion gap (AG) aids the differential diagnosis of acid-base disorders. Its value
has decreased, because of new analytical methods. Our goal was to compare AG reference …
has decreased, because of new analytical methods. Our goal was to compare AG reference …