A study of the impact of x-ray tube performance on angiography system imaging efficiency
M Dehairs, H Bosmans… - Physics in Medicine & …, 2020 - iopscience.iop.org
This work compared the impact of x-ray tube performance and automatic dose rate control
(ADRC) parameter selection on system imaging efficiency of two Siemens angiography …
(ADRC) parameter selection on system imaging efficiency of two Siemens angiography …
Effect of shape of automatic dose rate control and wedge compensation filter on radiation dose in an angiography system with a flat-panel detector
K Kakuta, S Nemoto, M Ikeda - Radiological Physics and Technology, 2023 - Springer
The purpose was to investigate air-kerma area product (PKA) and entrance surface air-
kerma rate (K˙ a, e) on the effect of the shape of automatic dose rate control (ADRC) in the …
kerma rate (K˙ a, e) on the effect of the shape of automatic dose rate control (ADRC) in the …
X-ray image quality and system exposure parameters for a hybrid Angio-MR system
M Dehairs, H Bosmans, M Leghissa… - Physics in Medicine & …, 2020 - iopscience.iop.org
This study investigates the exposure parameters and required x-ray tube output when
performing neurological procedures on a hybrid Angio-MR concept system proposed by …
performing neurological procedures on a hybrid Angio-MR concept system proposed by …
Generalized performance evaluation of x-ray image intensifier compared with a microangiographic system
GK Yadava, IS Kyprianou, S Rudin… - … 2005: Physics of …, 2005 - spiedigitallibrary.org
Standard objective parameters such as MTF, NPS, NEQ and DQE do not reflect complete
system performance, because they do not account for geometric unsharpness due to finite …
system performance, because they do not account for geometric unsharpness due to finite …
Overcoming x-ray tube small focal spot output limitations for high resolution region of interest imaging
SK Gupta, A Jain, DR Bednarek… - Medical Imaging 2012 …, 2012 - spiedigitallibrary.org
We investigate methods to increase x-ray tube output to enable improved quantum image
quality with a higher generalized-NEQ (GNEQ) while maintaining a small focal-spot size for …
quality with a higher generalized-NEQ (GNEQ) while maintaining a small focal-spot size for …
Understanding automated dose control in dynamic x-ray imaging systems
AJ Gislason-Lee, AG Davies… - European Congress …, 2014 - eprints.whiterose.ac.uk
Learning Objectives: To understand the inner workings of the automatic dose rate control
(ADRC) which controls radiographic factors during interventional procedures. This …
(ADRC) which controls radiographic factors during interventional procedures. This …
Radiographic and fluoroscopic X‐ray systems: Quality control of the X‐ray tube and automatic exposure control using theoretical spectra to determine air kerma and …
B Konst, J Nøtthellen, E Bilet… - Journal of Applied Clinical …, 2021 - Wiley Online Library
Purpose To develop a method to perform quality control (QC) of X‐ray tubes and automatic
exposure control (AEC) as a part of the QC of the radiographic and fluoroscopic X‐ray …
exposure control (AEC) as a part of the QC of the radiographic and fluoroscopic X‐ray …
Comprehensive assessment of patient image quality and radiation dose in latest generation cardiac x-ray equipment for percutaneous coronary interventions
AJ Gislason-Lee, C Keeble, D Egleston… - Journal of Medical …, 2017 - spiedigitallibrary.org
This study aimed to determine whether a reduction in radiation dose was found for
percutaneous coronary interventional (PCI) patients using a cardiac interventional x-ray …
percutaneous coronary interventional (PCI) patients using a cardiac interventional x-ray …
A statistical model of catheter motion from interventional x-ray images: application to image-based gating
The motion and deformation of catheters that lie inside cardiac structures can provide
valuable information about the motion of the heart. In this paper we describe the formation of …
valuable information about the motion of the heart. In this paper we describe the formation of …
[HTML][HTML] Characteristics of a new x-ray imaging system for interventional procedures: improved image quality and reduced radiation dose
RE Schernthaner, RR Haroun, S Nguyen… - Cardiovascular and …, 2018 - Springer
Purpose To compare image quality and radiation exposure between a new angiographic
imaging system and the preceding generation system during uterine artery embolization …