Cardioversion by internal electric shock of permanent atrial fibrillation
S Levy, P Bru, R Cointe, F Collet, M Metge… - … des Maladies du …, 1989 - europepmc.org
A new technique for cardioversion of chronic atrial fibrillation was used in 17 patients whose
arrhythmia had resisted all attempts at electrical and pharmacologycal cardioversion. Atrial …
arrhythmia had resisted all attempts at electrical and pharmacologycal cardioversion. Atrial …
Electrogram patterns predicting successful catheter ablation of ventricular tachycardia.
DM Fitzgerald, KJ Friday, JA Wah, R Lazzara… - Circulation, 1988 - Am Heart Assoc
Ventricular tachycardia in patients with remote myocardial infarction is thought to be due to
reentry. To improve the efficacy of catheter ablation, we sought to identify electrograms …
reentry. To improve the efficacy of catheter ablation, we sought to identify electrograms …
Transvenous ablation of atrioventricular conduction with a low energy power source.
E Rowland, D Cunningham, A Ahsan, A Rickards - Heart, 1989 - heart.bmj.com
A power source modified to increase voltage delivery and minimise arcing (for a given
energy) was used for transvenous ablation of atrioventricular conduction to control refractory …
energy) was used for transvenous ablation of atrioventricular conduction to control refractory …
[引用][C] The explosive expansion of ablative techniques for preventing arrhythmias: a personal view
G Fontaine - European Heart Journal, 1987 - academic.oup.com
Ablative techniques are based on the use of the energy of a physical agent to modify the
conduction in a localized area of myocardium in order to prevent the recurrence of badly …
conduction in a localized area of myocardium in order to prevent the recurrence of badly …
Catheter ablation of atrioventricular conduction
AW Nathan, DE Ward, DH Bennett, RS Bexton… - The Lancet, 1984 - Elsevier
Abstract 35 patients with refractory supraventricular arrhythmias were treated in three
centres by high-energy shocks delivered to the atrioventricular conduction system from a …
centres by high-energy shocks delivered to the atrioventricular conduction system from a …
The effects of high-energy DC shocks delivered to ventricular myocardium
G Fontaine - Catheter Ablation of Cardiac Arrhythmias: Basic …, 1988 - Springer
Endocardial catheter fulguration is a new method for the treatment of cardiac arrhythmias
which has been used to interrupt the AV conduction system, to prevent rapid ventricular …
which has been used to interrupt the AV conduction system, to prevent rapid ventricular …
In vitro and in vivo effects within the coronary sinus of nonarcing and arcing shocks using a new system of low-energy DC ablation.
R Lemery, TK Leung, E Lavallee, A Girard, M Talajic… - Circulation, 1991 - Am Heart Assoc
DC shocks within the coronary sinus have been abandoned because of the risk of cardiac
rupture and tamponade. Catheter ablation using DC energy to electrodes straddling the …
rupture and tamponade. Catheter ablation using DC energy to electrodes straddling the …
Low-energy ablation of accessory pathways in cases for which the radiofrequency approach had failed
D Katritsis, S Heald, Y Bashir, D Ward… - The American journal of …, 1993 - Elsevier
The introduction of radiofrequency energy for catheter ablation of accessory pathways has
offered certain advantages over high-energy direct-current shocks. With this approach …
offered certain advantages over high-energy direct-current shocks. With this approach …
Direct current shock therapy of cardiac arrhythmias.
P Szekely, GA Batson, DC Stark - British Heart Journal, 1966 - ncbi.nlm.nih.gov
RESULTS The arrhythmias treated were atrial fibrillation, atrial flutter, atrial tachycardia,
ventricular tachy-cardia, and ventricular fibrillation. The immediate results are summarized in …
ventricular tachy-cardia, and ventricular fibrillation. The immediate results are summarized in …
An Experimental Device for Low-Energy, Precise Ablation of AV Conduction.
P Tarjan, B Boveja, D Cohen… - Pacing & Clinical …, 1986 - search.ebscohost.com
A combination suction catheter-bipolar lead system permits precise ablation of AV
conduction with low energy. The electrode is positioned to maximize the bipolar His …
conduction with low energy. The electrode is positioned to maximize the bipolar His …