Update on value of the anion gap in clinical diagnosis and laboratory evaluation
PH Lolekha, S Vanavanan, S Lolekha - Clinica chimica acta, 2001 - Elsevier
Anion gap (AG) is a calculated value commonly used in clinical practice. It approximates the
difference between the concentration of unmeasured anions (UA) and unmeasured cations …
difference between the concentration of unmeasured anions (UA) and unmeasured cations …
Low anion gap.
RL Jurado, C del Rio, G Nassar, J Navarette… - Southern medical …, 1998 - europepmc.org
Background The purpose of this review is to provide a differential diagnosis for a low anion
gap. Methods We describe the anatomy of the anion gap. Also, we follow-up with a review of …
gap. Methods We describe the anatomy of the anion gap. Also, we follow-up with a review of …
[HTML][HTML] Clinical usefulness of the serum anion gap
S Lee, KP Kang, SK Kang - … & Blood Pressure: E & BP, 2006 - synapse.koreamed.org
The anion gap in the serum is useful in the interpretation of acid-base disorders and in the
diagnosis of other conditions. In the early 1980s, ion-selective electrodes for specific ionic …
diagnosis of other conditions. In the early 1980s, ion-selective electrodes for specific ionic …
Reference ranges of electrolyte and anion gap on the Beckman E4A, Beckman Synchron CX5, Nova CRT, and Nova Stat Profile Ultra
PH Lolekha, S Vanavanan, N Teerakarnjana… - Clinica chimica acta, 2001 - Elsevier
The widespread use of ion-selective electrode causes the reference range of the anion gap
(AG) to be lowered from 8–16 to 3–11 mmol/l. The use of the outdated reference range (8 …
(AG) to be lowered from 8–16 to 3–11 mmol/l. The use of the outdated reference range (8 …
Value of the anion gap in clinical diagnosis and laboratory evaluation.
PH Lolekha, S Lolekha - Clinical chemistry, 1983 - academic.oup.com
We report the incidence of normal (50.4%), increased (46.7%), and decreased (2.9%) anion
gap among hospitalized patients in a retrospective study. The mean and range of increased …
gap among hospitalized patients in a retrospective study. The mean and range of increased …
Wide variation in serum anion gap measurements by chemistry analyzers
WD Paulson, WL Roberts, AA Lurie… - American journal of …, 1998 - academic.oup.com
The traditional anion gap [AG= Na–Cl–(total CO2)] mean value of 12 mEq/L was established
during the 1970s with analyzer methods that are no longer used widely. No studies have …
during the 1970s with analyzer methods that are no longer used widely. No studies have …
Anion gap reference intervals show instrument dependence and weak correlation with albumin levels
B Pratumvinit, L Lam, N Kongruttanachok… - Clinica Chimica …, 2020 - Elsevier
Background Anion gap (AG) aids the differential diagnosis of acid-base disorders. Its value
has decreased, because of new analytical methods. Our goal was to compare AG reference …
has decreased, because of new analytical methods. Our goal was to compare AG reference …
Anion gap among patients of multiple myeloma and normal individuals
S Mansoor, I Siddiqui, S Adil, GN Kakepoto, Z Fatmi… - Clinical …, 2007 - Elsevier
OBJECTIVE:: To compare the Anion gap between patients of multiple myeloma and normal
individuals presenting at a tertiary care hospital. DESIGN AND METHODS:: This is a …
individuals presenting at a tertiary care hospital. DESIGN AND METHODS:: This is a …
[引用][C] The Anion Gap: A Reappraisal
T Badrick, PE Hickman - American journal of clinical pathology, 1992 - academic.oup.com
The" anion gap" refers to the concentration of unmeasured anions in blood. The most
commonly used formula to measure this is [Na]—[C1]—[HCO3] and a typical reference …
commonly used formula to measure this is [Na]—[C1]—[HCO3] and a typical reference …
Influence of hypoalbuminemia or hyperalbuminemia on the serum anion gap
M Feldman, N Soni, B Dickson - Journal of Laboratory and Clinical …, 2005 - Elsevier
Background: Conflicting data exist as to what extent hypoalbuminemia reduces the anion
gap; estimates range from 1.5 to 2.5 mM per g/dL decrease in serum albumin. Methods: We …
gap; estimates range from 1.5 to 2.5 mM per g/dL decrease in serum albumin. Methods: We …