The accuracy of absorbed dose estimates in tumours determined by quantitative SPECT: a Monte Carlo study

M Ljungberg, K Sjögreen-Gleisner - Acta oncologica, 2011 - Taylor & Francis
… Today, quantitative SPECT combined with registered anatomical CT images provide data …
the absorbed energy and the absorbed dose. Absorbed dose calculation from SPECT images …

Estimation of the total effective dose from low-dose CT scans and radiopharmaceutical administrations delivered to patients undergoing SPECT/CT explorations

C Montes, P Tamayo, J Hernandez… - Annals of nuclear …, 2013 - Springer
dose delivered by SPECT/CT scans, so this study aimed (a) to determine the radiation exposure
of patients undergoing SPECT/CT … men and women organ-absorbed doses. The D T,R …

SPECT/CT radiation dosimetry

M Ferrari, P De Marco, D Origgi, G Pedroli - Clinical and Translational …, 2014 - Springer
… also shown together with the mean absorbed dose per unit of … need of higher doses for the
CT component of SPECT/CT is … dose range from 2 to 4 mSv for SPECT-guided low-dose CT […

Radiation risk and protection of patients in clinical SPECT/CT

G Brix, EA Nekolla, M Borowski, D Noßke - European journal of nuclear …, 2014 - Springer
dose quantity is the absorbed dose D T (given in the unit gray, 1 Gy = 1 J/kg), which is defined
as the radiation energy absorbed … For radiological protection purposes, the absorbed dose

3D absorbed dose calculations based on SPECT: evaluation for 111-In/90-Y therapy using Monte Carlo simulations

M Ljungberg, E Frey, K Sjögreen, X Liu… - Cancer Biotherapy …, 2003 - liebertpub.com
… Patient movements need to be accounted for, so that SPECT data and CT data match each
… the CT and SPECT images.For the purposes of this study, a perfectly registered CT was …

Spect/ct

AK Buck, S Nekolla, S Ziegler, A Beer… - Journal of Nuclear …, 2008 - Soc Nuclear Med
CT can increase the overall radiation dose by up to 14 mSv (11). Low-dose CT is associated
with relatively low radiation doses … ascertaining the absorbed dose delivered during …

Radiation exposure levels of routine SPECT/CT imaging protocols

I Rausch, FG Füchsel, C Kuderer, M Hentschel… - European journal of …, 2016 - Elsevier
… the patients by the fractions of photons absorbed within the body tissues and by scattered …
dose CT and subsequent low-dose SPECT/CT by a single comprehensive full-dose SPECT/CT

Radiation dose management in CT, SPECT/CT and PET/CT techniques

S Mattsson, M Söderberg - Radiation protection dosimetry, 2011 - academic.oup.com
… patient dose estimation and magnitude of patient dose In CT, the estimates of absorbed
doses … tissues and effective doses are based on the quantities (13) : the weighted CT air-kerma …

Method for fast CT/SPECT-based 3D Monte Carlo absorbed dose computations in internal emitter therapy

SJ Wilderman, YK Dewaraja - IEEE transactions on nuclear …, 2007 - ieeexplore.ieee.org
… DPM (Dose Planning Method) [6] (originally developed specifically for fast absorbed dose
… specifically for efficient computation of absorbed dose distributions in CT-derived, voxelized …

Accurate dosimetry in 131I radionuclide therapy using patient-specific, 3-dimensional methods for SPECT reconstruction and absorbed dose calculation

YK Dewaraja, SJ Wilderman, M Ljungberg… - Journal of Nuclear …, 2005 - Soc Nuclear Med
… , CT is also used to derive attenuation maps for the SPECT … Typically, in patient imaging,
the SPECT and CT acquisitions … In phantom simulations described here, the SPECT image …