[HTML][HTML] Appropriate and inappropriate therapy in patients with single-or multi-chamber implantable cardioverter-defibrillators

AL Burger, H Schmidinger, R Ristl… - Hellenic Journal of …, 2020 - Elsevier
… 30, 31, 32 In the present study, VVI-ICD patients received significantly more inappropriate
therapies than DDD-ICD and CRT-D patients. However, Kaplan Meier analysis did not show a …

Technological and clinical challenges in lead placement for cardiac rhythm management devices

M Albatat, J Bergsland, H Arevalo, HH Odland… - Annals of Biomedical …, 2020 - Springer
… In this paper, focus will be on permanently implanted cardiac … by creating devices for
multi-chamber leadless pacing. … Modern ICDs have single or dual-chamber pacing functions …

The role of implantable cardioverter-defibrillators and sudden cardiac death prevention: indications, device selection, and outcome

I Goldenberg, DT Huang, JC Nielsen - European heart journal, 2020 - academic.oup.com
… surgically to more advanced technologies of multi-chamber … the appropriate decision to
implant either a single- or dual-… appropriate and inappropriate shocks, and mortality between …

Novel ICD programming and inappropriate ICD therapy in CRT-D versus ICD patients: a MADIT-RIT sub-study

V Kutyifa, JP Daubert, C Schuger… - Circulation …, 2016 - Am Heart Assoc
… on ICD programming to reduce inappropriate ICD therapy in patients implanted with CRT-D …
robustness of our findings, including all relevant covariates in the multivariate model. This …

Atrial arrhythmias in patients with arrhythmogenic right ventricular cardiomyopathy: Prevalence, echocardiographic predictors, and treatment

R Cardona‐Guarache, M Åström‐Aneq… - Journal of …, 2019 - Wiley Online Library
… , and one patient (4%) suffered inappropriate implantable … who are refractory to single or
double drug therapy, we offered … However, multi-chamber intracardiac thrombi and systemic …

Pacemakers, defibrillators, and cardiac resynchronization therapy

H Ayinde, MD Sabayon, MS Lloyd - Handbook of Inpatient Cardiology, 2020 - Springer
… knowledge necessary to manage patients with cardiac implantable … generic code for
anti-bradycardia and multi-chamber pacing … AV conduction in single or dual chamber pacemakers. …

Downgrade from CRT-D to CRT-P at time of generator replacement: a true clinical conundrum or just an academic debate?

JRD Clarke, DJ Friedman - Journal of Interventional Cardiac …, 2023 - Springer
… Approximately 80% patients with a … for inappropriate and appropriate ICD therapies compared
to their non-CRT ICD counterparts [5, 6]. The reduction in rates of appropriate ICD therapy

Impact and modifiers of ventricular pacing in patients with single ventricle circulation

H Chubb, A Bulic, D Mah, JP Moore, J Janousek… - Journal of the American …, 2022 - jacc.org
… those with single-chamber vs multi-chamber pacing systems (84% [… were implanted as the
initial ventricular system in 8 (3.4%) patients. … relevant to the contents of this paper to disclose. …

Fitness to Drive After Syncope and/or in Cardiovascular Disease–An Overview and Practical Advice

T Pezawas - Current problems in cardiology, 2021 - Elsevier
… and implantable cardioverter defibrillator (ICD) intervention was described for patients with
reduced left ventricular function and for patients … on appropriate and inappropriate device …

Importance of diastolic function for the prediction of arrhythmic death: a prospective, observer-blinded, long-term study

T Pezawas, AL Burger, T Binder… - Circulation: Arrhythmia …, 2020 - Am Heart Assoc
… prevention with an implantable cardioverter-defibrillator (ICD) in patients with severely …
Appropriate ICD therapy without ventricular tachycardia acceleration that failed to save the patient