[HTML][HTML] Evaluation of ultrasound point shear wave elastography reliability in an elasticity phantom

SR Sultan, A Alghamdi, R Abdeen, F Almutairi - Ultrasonography, 2022 - ncbi.nlm.nih.gov
… Key point This study assessed the reliability of ultrasound pSWE in an elasticity phantom
Our findings suggest that ultrasound pSWE is a reliable and reproducible method for …

Measuring shear-wave speed with point shear-wave elastography and MR elastography: a phantom study

R Kishimoto, M Suga, A Koyama, T Omatsu… - BMJ open, 2017 - bmjopen.bmj.com
… Our study was limited to a single ultrasound elastography … palpation of tissue elasticity to
evaluate pathophysiological states, … , so as to increase the reliability of multimodal elastography. …

Effect of depth on ultrasound point shear wave elastography in an elasticity phantom

FF Almutairi, R Abdeen, J Alyami, SR Sultan - Applied Sciences, 2022 - mdpi.com
reliability and accuracy of point Shear Wave elastography (pSWE) measurements of an
elasticity phantom. … Therefore, phantom studies could be ideal for evaluating the performance of …

Intra-and inter-operator reproducibility of US point shear-wave elastography in various organs: evaluation in phantoms and healthy volunteers

R Kishimoto, K Kikuchi, A Koyama, J Kershaw… - European …, 2019 - Springer
… Two operators measured the SWS of five elasticity phantomsUltrasound (US) elastography
has been widely used to … In conclusion, our phantom study indicated the high reliability of …

[HTML][HTML] Reproducibility of shear wave elastography among operators, machines, and probes in an elasticity phantom

AI Alrashed, AM Alfuraih - Ultrasonography, 2021 - ncbi.nlm.nih.gov
… of shear wave elastography (SWE) among operators, machines, and probes in a phantom,
and to evaluate the effect of depth of the embedded inclusions and the accuracy of the …

Accuracy and precision of ultrasound shear wave elasticity measurements according to target elasticity and acquisition depth: A phantom study

CH Suh, HM Yoon, SC Jung, YJ Choi - PLoS One, 2019 - journals.plos.org
… As shear wave elastography is currently being utilized in clinical practice [4–10],
determination of its … This study evaluated the accuracy and precision of US shear wave

Repeatability of shear wave elastography in liver fibrosis phantomsEvaluation of five different systems

A Mulabecirovic, AB Mjelle, OH Gilja, M Vesterhus… - PLoS …, 2018 - journals.plos.org
Elasticity itself is often not visualized (Point shear wave … The phantom was compatible with
the ultrasound shear wave … ), VsN (Reliability Index for shear wave velocity measurement) and …

Performances and limitations of several ultrasound-based elastography techniques: a phantom study

S Franchi-Abella, C Elie, JM Correas - Ultrasound in Medicine & Biology, 2017 - Elsevier
… strain and shear wave (SW) elastography performance in terms of accuracy by performing
… We assumed that the elastography phantom was homogeneous, elastic, isotropic and …

Comparison of shear wave velocities on ultrasound elastography between different machines, transducers, and acquisition depths: a phantom study

HJ Shin, MJ Kim, HY Kim, YH Roh, MJ Lee - European radiology, 2016 - Springer
… As the CV becomes smaller, the reliability increases in any single … the evaluation of superficial
organs in SSI [14]. Our study is different, because we used a phantom of known elasticity

[HTML][HTML] Comparison of 2 shear wave elastography systems in reproducibility and accuracy using an elasticity phantom

JH Woo, EY Ko, BK Han - Medicine, 2021 - journals.lww.com
… performed ultrasound (US) elastography examinations for the phantom lesions … evaluate
diagnostic performance, but we could analyze the accuracy in measuring the known elasticity