Antimicrobial lock solutions for the prevention of catheter-related infection in patients undergoing haemodialysis: study protocol for network meta-analysis of …

J Zhang, RK Li, KH Chen, L Ge, JH Tian - BMJ open, 2016 - bmjopen.bmj.com
… -citrate catheter lock solutions reduced the risk of CRI, and another meta-analysis showed
that participants using ethanol locks had a lower CRBSI-rate per 1000 catheterconcentration

Managing dysfunctional central venous access devices: a practical approach to urokinase thrombolysis

M Kumwenda, L Dougherty, H Spooner… - British Journal of …, 2018 - magonlinelibrary.com
locking solution (eg heparin, 4% citrate, low molecular weight … been reported with the use
of high-concentration citrate (46.7%) … The authors recommend that prospective studies be …

[图书][B] Physicochemical compatibility and stability of 4% sodium citrate and ethanol when stored in silicone coated and non-silicone coated glass containers

M Krishnakumar - 2020 - search.proquest.com
… For low concentration lock solutions, when a lock is renewed the new … sodium citrate
instead of heparin as the intradialytic anticoagulant in hemodialysis catheters(41). Additionally, …

Impact of lock solutions on the mechanical performance of polyurethane central venous catheters: A comparative study

A Khzam, J Saunier, L Carpentier, A Mignot… - Medical Engineering & …, 2023 - Elsevier
… Ethanol locks are used with hemodialysis catheters and other … solution composed of
cyclotaurolidine and citrate (4%). Other … The polymer concentration was 2 mg/mL, and 100 μL …

[PDF][PDF] Preventing Bloodstream Infections in Hemodialysis Patients

MH Mokrzycki - kidneynews.org
… series, which used a relatively high concentration of gentamicin (… 3 trial, the Lock-It 100 study
of taurolidine-heparin-citrate lock (… catheter lock solution reduces hemodialysis catheter loss …

Pre-Emptive Antimicrobial Locks Decrease Long-Term Catheter-Related Bloodstream Infections in Hemodialysis Patients

A Blanco-Di Matteo, N Garcia-Fernandez… - Antibiotics, 2022 - mdpi.com
locking with an antimicrobial and low-dose heparin is more effective and safer when
compared to other lock solutions (eg, citrate… but could complicate the comparison of our results. …

Antibiotic locks for the treatment of catheter‐related blood stream infection: still more hope than data

L Labriola - Seminars in Dialysis, 2019 - Wiley Online Library
… the gentamicin concentration is lower (5 mg/ml),22 or when citrate is used instead heparin.20
… The permanent spillage of a highly concentrated lock solution produces significant blood …

Pre-Emptive Antimicrobial Locks Decrease Long-Term Catheter-Related Bloodstream Infections in Hemodialysis Patients.

BD Matteo, N Garcia-Fernandez… - Antibiotics (2079 …, 2022 - search.ebscohost.com
locking with an antimicrobial and low-dose heparin is more effective and safer when
compared to other lock solutions (eg, citrate… but could complicate the comparison of our results. …

Applying a Successful New Protocol for Storing a Tissue Plasminogen Activator for Locking Dysfunctional Permcath: A Single-Center Study

A Hamad, S Khalifa, H Bouanane, H Tolba… - Blood …, 2017 - karger.com
… maintain good blood flow in dialysis catheters. We generally … the catheter open including
Taurolidine citrate with heparin - … the name of the product with the concentration as 5 mg/5 mL …

Lock therapy in prevention and treatment of catheter-associated bloodstream infection: integrative review

KA Tresso, BN Santos, FTMM Braga… - Acta Paulista de …, 2023 - SciELO Brasil
studies performed with hemodialysis catheters or catheters … placebo-controlled trial (TAURCAT
study) of citrate lock solution for … The concentration of the antibiotic in the lock therapy can …