Construction of Chinese adult male phantom library and its application in the virtual calibration of in vivo measurement

Y Chen, R Qiu, C Li, Z Wu, J Li - Physics in Medicine & Biology, 2016 - iopscience.iop.org
… convert the polygon phantom to the voxel phantom. This … of the detecting system were not
modeled in Monte Carlo simulation in … E 1998 Calibration of in vivo measurement systems and …

Monte Carlo modeling and simulation of a new 3D printed phantom for WBC calibration with ballistic gel as a tissue substitute

EMR de Andrade, L Paixão, BM Mendes… - Applied Radiation and …, 2024 - Elsevier
… ) systems are used for in vivo monitoring in occupational internal dosimetry, typically calibrated
using physical anthropomorphic phantoms. … the Reference Female Phantom for Internal …

Age-dependent calibration factors for in-vivo monitoring of 131I in thyroid using Monte Carlo simulations

JM Gómez-Ros, M Moraleda, P Teles, K Tymińska… - … Measurements, 2019 - Elsevier
… 4, compared with the values obtained using the voxel phantom … with the voxel phantoms
and the calibration phantoms are … ) for the thyroid calibration phantoms SCK-CEN and IRSN …

Real-time, acquisition parameter-free voxel-wise patient-specific Monte Carlo dose reconstruction in whole-body CT scanning using deep neural networks

Y Salimi, A Akhavanallaf, Z Mansouri, I Shiri… - European Radiology, 2023 - Springer
… We proposed a novel method for voxel dose map calculation using deep neural networks.
This … out within acceptable computational time compared to lengthy Monte Carlo calculations. …

Monte Carlo simulations of a standing geometry whole body counter: Effects of skeletal sampling, age, sex and phantom size on calibration

CS Charubala, V Santhanakrishnan… - Radiation Physics and …, 2024 - Elsevier
Voxel files for FLUKA Monte Carlo code are created from the data provided by ICRP … reference
phantoms by ICRP, numerical calibration of in-vivo monitoring systems using Monte Carlo

Monte Carlo calculation of whole body counter efficiency factors for different computational phantoms

CVG Ferreira, JS Piedade, MRD Prado… - Applied Radiation and …, 2023 - Elsevier
… To configure the VMC code to simulate the WBC system using different voxel phantoms, a …
the BOMAB phantom as a calibration device for in-vivo whole-body measurement systems, it …

Monte Carlo dose simulation for in-vivo X-ray nanoscopy

F Wagner, M Thies, M Karolczak, S Pechmann… - Bildverarbeitung für die …, 2022 - Springer
phantom of a mouse leg during an in-vivo acquisition. That … this work to calibrate the simulated
dose values to the XRM system. … We derive densities directly from voxel intensities using a …

[HTML][HTML] Virtual calibration of whole-body counters to consider the size dependency of counting efficiency using Monte Carlo simulations

MS Park, HS Kim, J Yoo, CH Kim, WI Jang… - Nuclear Engineering and …, 2021 - Elsevier
Monte Carlo methods have been used previously to calibrate in vivo measurement systems.
simulations with the computational phantoms of different sizes developed by different …

Measurements and Monte Carlo simulations of 241Am activities in three skull phantoms: EURADOS-USTUR collaboration

MA López, P Nogueira, T Vrba, RJ Tanner… - Health …, 2019 - journals.lww.com
Monte Carlo calibration of body counters as an alternative method when appropriate physical
phantoms … the application of MC techniques and voxel phantoms for in vivo monitoring of x-…

Counting efficiencies determined by Monte Carlo methods for in vivo measurement of 131I activity in thyroid

MS Park, TE Kwon, WH Ha, CH Kim, S Park… - Health …, 2019 - journals.lww.com
calibration is performed using a standard neck phantom … ) to +15 voxels on the frontal surface
of the phantoms. The … in vivo measurement systems, such as whole-body counting (WBC) …