Endovascular stent-induced alterations in host artery mechanical environments and their roles in stent restenosis and late thrombosis

J Wang, X Jin, Y Huang, X Ran, D Luo… - Regenerative …, 2018 - academic.oup.com
… Before solving these problems, we should first understand the interaction between the stent
… A characteristic pattern with time on the basis of the in-stent stenosis change. (a) Nine cross-…

Influences of plaque eccentricity and composition on the stent–plaque–artery interaction during stent implantation

L Wei, Q Chen, Z Li - Biomechanics and Modeling in Mechanobiology, 2019 - Springer
… the mechanics of stent–plaque–artery interaction during stentstent often changes the local
mechanical environment (Dabus … stent foreshortening; thus, in order to cover the stenosis part …

Mechanical interaction of an expanding coiled stent with a plaque-containing arterial wall: a finite element analysis

TR Welch, RC Eberhart, S Banerjee… - Cardiovascular …, 2016 - Springer
… in the expansion of stent in an asymmetrical stenosed artery. Computational methods have
… Using this model we examined changes in von Mises stresses, principal stresses and …

Effect of longitudinal anatomical mismatch of stenting on the mechanical environment in human carotid artery with atherosclerotic plaques

Z Fan, X Liu, A Sun, N Zhang, Z Fan, Y Fan… - Medical Engineering & …, 2017 - Elsevier
… (LAM) of stenting (ie, a stenotic artery segment is not fully … VMS on the artery-stent interaction
surface and within the lipid … Moreover, VMS on the lipid plaque showed large changes with …

Bending analysis of stented coronary artery: the interaction between stent and vessel

X Shen, YQ Deng, S Ji, HF Zhu, JB Jiang… - … of Mechanics, 2019 - cambridge.org
… of a stent could influence the mechanical environment of the … stent deployment cannot explain
the clinical fact that stenting … These changes could lead to ISR at the stent extremes. As a …

Fluid-structure interaction in coronary stents: a discrete multiphysics approach

AM Mohammed, M Ariane, A Alexiadis - ChemEngineering, 2021 - mdpi.com
… or polymer stent is deployed to open the stenosed artery or … study the mechanical deformation
of the coronary stent and its … distribution within the local hemodynamic environment as well …

… study of effects of material properties, strain level, and friction coefficient on smart stent behavior and peripheral artery performance during the interaction process

F Nematzadeh - Journal of Intelligent Material Systems and …, 2022 - journals.sagepub.com
… internal curvature of the stents, displays the SIM change and is … mechanical enactment for
the Peripheral Artery Smart stent … formation between arteries, stenosis degree of arteries, the …

A mechanobiological model for damage-induced growth in arterial tissue with application to in-stent restenosis

B Fereidoonnezhad, R Naghdabadi… - … of the Mechanics and …, 2017 - Elsevier
… Morphological changes occurring within the arterial wall due to stent-induced mechanical
… (grow/atrophy) in response to an environmental change, whereby the mass of the system is …

Nitinol stents in the femoropopliteal artery: a mechanical perspective on material, design, and performance

K Maleckis, E Anttila, P Aylward, W Poulson… - Annals of biomedical …, 2018 - Springer
… current understanding of the FPA mechanical environment. … stent design profoundly influences
stent-artery interaction, … , with the amount of change dependent on stent characteristics. …

Haemodynamics and flow modification stents for peripheral arterial disease: a review

E Kokkalis, N Aristokleous, JG Houston - Annals of Biomedical …, 2016 - Springer
… The interaction between stent struts and arterial cells in contact… of arterial blood flow describes
the mechanical properties … studies in stenosed and non-stenosed porcine models, as well …