[HTML][HTML] Medium-and long-term follow-up of transcatheter closure of ruptured sinus of Valsalva aneurysm in Central Europe population
M Galeczka, J Glowacki, N Yashchuk, I Ditkivskyy… - Journal of …, 2019 - Elsevier
… We applied 22 duct, 3 muscular, and 1 atrial septal Amplatzer … with patch closure at both ends
of the defect remains the … by Hourihan with a double umbrella device in 1992 [4]. Since then…
of the defect remains the … by Hourihan with a double umbrella device in 1992 [4]. Since then…
Atrial Septal Defects
ND Hahurij, R Bökenkamp - … : Fetal, Pediatric, and Adult Congenital Heart …, 2023 - Springer
… The defect representing failure of closure of the primary atrial … ature is scarce; however, the
use of agents like digoxin and diuretics … was performed with a “double umbrella” device [65], …
use of agents like digoxin and diuretics … was performed with a “double umbrella” device [65], …
Transcatheter Closure of Perimembranous Ventricular Septal Defects Using Dual Wire-Maintaining Technique
XD Xu, LM Gao, Y Bai, ZG Zhang, XH You… - Heart, Lung and …, 2017 - Elsevier
… (VSD) closure using a double umbrella device in 1988[1], … ) postoperative residual defects;
(5) left ventricle to right atrial shunts. … reference data for further clinical application. Finally, the …
(5) left ventricle to right atrial shunts. … reference data for further clinical application. Finally, the …
[HTML][HTML] Percutaneous closure of symptomatic large tricuspid paravalvular regurgitation using two muscular VSD occluders
A Mukherji, R Anantharaman, R Subramanyan - Indian Heart Journal, 2017 - Elsevier
… closure of paravalvular defect in three patients of aortic paravalvular regurgitation using the
Rashkind-Cuaso double umbrella … closure of a large tricuspid PVLL using Amplatzer atrial …
Rashkind-Cuaso double umbrella … closure of a large tricuspid PVLL using Amplatzer atrial …
Occlusion Devices for Cardiovascular Disease
Y Zeng, Y Zhang, C Tu - Application of Biomaterials in the Treatment of …, 2024 - Springer
… in five major applications, the atrial septal defect, the patent … Recently, the initial clinical
results also suggested that GCO … ends of the MP35N “double-umbrella” framework. The device …
results also suggested that GCO … ends of the MP35N “double-umbrella” framework. The device …
[PDF][PDF] Recent developments in next-generation occlusion devices
… The first use of stainless steel in occlusion devices was the double umbrella occluder reported
… , and ZM Hijazi, A new device to close secundum atrial septal defects: First clinical use to …
… , and ZM Hijazi, A new device to close secundum atrial septal defects: First clinical use to …
Near-Infrared Remotely Controllable Shape Memory Biodegradable Occluder Based on Poly(l-lactide-co-ε-caprolactone)/Gold Nanorod Composite
Z Xiang, J Zhang, C Zhou, B Zhang… - … Applied Materials & …, 2023 - ACS Publications
… ), such as atrial septal defect (ASD), ventricular septal defect (… to block the heart defect at
the initial stage like conventional … Finally, “Double Umbrella” structure ASD occluders were …
the initial stage like conventional … Finally, “Double Umbrella” structure ASD occluders were …
Hybrid atrial septal defect closure
ZM Hijazi - Fetal and Hybrid Procedures in Congenital Heart …, 2016 - Springer
… the first transcatheter closure of a secundum ASD in a patient using a double-umbrella device,
device closure … [22] reported the use of TEE guidance of percardiac closure of intracardiac …
device closure … [22] reported the use of TEE guidance of percardiac closure of intracardiac …
More than 3 decades quest for the ideal device to close ventricular septal defects
A Fraisse, C Bautista-Rodriguez - International …, 2020 - internationaljournalofcardiology.com
… for PM and muscular VSD closure. The initially used Rashkind double umbrella devices and
… We use cookies to help provide and enhance our service and tailor content. To update your …
… We use cookies to help provide and enhance our service and tailor content. To update your …
Interventions for congenital heart disease
DWM Muller - Interventional Cardiology and Cardiac …, 2019 - taylorfrancis.com
… These procedures include closure of atrial and ventricular septal defects, patent ductus …
(BIO-STAR, NMT Medical, Boston, MA, USA). Complications following use of these devices have …
(BIO-STAR, NMT Medical, Boston, MA, USA). Complications following use of these devices have …