Update on percutaneous and perventricular device closure of congenital ventricular septal defect

JS Lozier, M Sati, IM Cheifetz… - Expert Review of …, 2023 - Taylor & Francis
… Typically, the VSD is repaired via the right atrium through the … A Rashkind double umbrella
device was used to close VSDs in … By closing this message, you are consenting to our use of …

Intraoperative customized double-patch device with twin sutures for multiple muscular septal defects

GG Salve, SA Jain, B Sharma… - Interactive …, 2018 - academic.oup.com
… Second, we closed all the defects through the right atrium using an ‘Intraoperative … use of
intraoperative VSD device (Rashkind double-umbrella device) for isolated or multiple defects

Simultaneous transcatheter closure of multiple atrial septal defects using dual Amplatzer septal occluder devices

Y Yang, Z Xu, S Jiang, S Zhao, G Zhang, J Jin… - … Journal of the Medical …, 2016 - Elsevier
defect or other defects were found by 2D TTE or TEE, and occasionally defects were found
by 2D TTE after closing the first defect in … a smaller defect, and closing the larger defect first. …

TEE in the Hemodynamic and Electrophysiology Suite

AG Rochon, R Ibrahim, A Dore - Transesophageal …, 2016 - taylorfrancis.com
first review the use of TEE during percutaneous closure of patent foramen ovale (PFO), atrial
septal defects (ASDs), ventricular septal defects (… of a double-umbrella-type closure device …

CHEM Biomedical Applications

WM Sokolowski, N Chirani - Cold Hibernated Elastic Memory …, 2018 - taylorfrancis.com
first transcatheter closure of an ASD using double umbrella disks [21]. Since then, many devices
have been developed to close such defects [… place to close to close the interatrial defect. …

Interventional VSD-Closure with the Nit-Occlud® Lê VSD-Coil in 110 Patients: Early and Midterm Results of the EUREVECO-Registry

NA Haas, L Kock, H Bertram, R Boekenkamp… - Pediatric …, 2017 - Springer
… [1] who used a Rashkind double-umbrella device. The Amplatzer … Thereafter, the widespread
use of the Amplatzer … through the defect, and one defect was too large to be closed with the …

[HTML][HTML] Early and Mid-Term Follow-Up Results After Transcatheter Closure of Secundum Atrial Septal Defect

B Kılınç, AG Eroğlu, İL Saltık - Turkish Archives of Pediatrics, 2022 - ncbi.nlm.nih.gov
… Transcatheter closure of the secundum ASD was first described in … defect of up to 26 mm
with a double umbrella device. In the last 30 years, with the development of devices, their use

[PDF][PDF] Cardiac Remodeling after Surgical Patch Closure of Adult Congenital Atrial Septal Defects: Perspective of Bangladesh

MM Rahman, MR Alam, AK Al-Miraj - Glob Acad J Med Sci, 2022 - gajrc.com
… surgical closure of atrial septal defect in all age group and degree of cardiac remodeling was
better in early … for non-commercial use provided the original author and source are credited. …

[PDF][PDF] Management of intractable hemolysis after transcatheter ventricular septal defect closure with Nit Occlud® Lê ventricular septal defect coil

M Saygı, FS Şengül, İC Tanıdır, T Kasar… - Turk Gogus Kalp …, 2016 - tgkdc.dergisi.org
… a Rashkind double-umbrella was used for the closure. Although … following transcatheter
closure of atrial septal defects (ASDs), … Therefore, we believe that it is more advisable to use a …

[HTML][HTML] Effectiveness and safety of transcatheter atrial septal defect closure in adults with systemic essential hypertension

I Świątkiewicz, Ł Bednarczyk, M Kasprzak… - Journal of Clinical …, 2022 - mdpi.com
atrial septal defect (ASD) can unfavorably affect the hemodynamics and transcatheter ASD
closure … ASDC in adults with HTN in real-world clinical practice. Right ventricular (RV) reverse …