[HTML][HTML] Exploring the impact of optical corrections on visual functions in myopia control–a scoping review

SD Janarthanan, K Samiyullah… - International …, 2024 - Springer
… sensitivity function with CSV1000 (Vector Vision) under mesopic and photopic conditions, …
These review results were obtained after compiling the results from the published literature, …

Visual function after implantation of a presbyopia-correcting trifocal intraocular lens

JF Alfonso, L Fernández-Vega-Cueto… - Ophthalmic …, 2020 - karger.com
… They assessed photopic and mesopic vision in 25 eyes … contrast sensitivity and photopic
and mesopic defocus curves in … of the patients after the nature and possible consequences of …

Contribución óptica y neural en la función visual en adaptación mesópica y fotópica

RF Sánchez, LF Calderari, LA Issolio - 2023 - ri.conicet.gov.ar
… on contrast sensitivity for mesopic to photopic lighting. MTFs … we study the relative contribution
of optical and neural effects … distance visual acuity of 20/20 or higher, spherical refraction …

Long-term objective and subjective outcomes following bilateral implantation of diffractive bifocal or trifocal intraocular lenses

V Vargas, JL Alio, RF Oliveira… - European Journal of …, 2021 - journals.sagepub.com
… CS under photopic and mesopic conditions because after … a major impact on patient quality
of life after the implantation of … stable restoration of visual acuity after microincisional cataract …

[HTML][HTML] … of a Segmented Extended-Depth-of-Focus Intraocular Lens under the Influence of Different Values of Spherical Aberration Generated by Refractive Surgery

L Salvá, S García, S García-Delpech… - Journal of Clinical …, 2023 - mdpi.com
impact of high-order aberrations on visual performance is more important in mesopic conditions
than in photopic … orientations did not significantly change visual acuity [41]. However, the …

Visual acuity and patient satisfaction at varied distances and lighting conditions after implantation of an aspheric diffractive multifocal one-piece intraocular lens

DH Chang - Clinical Ophthalmology, 2016 - Taylor & Francis
… near visual acuity under photopic as well as mesopic lighting … Abbe number can reduce
chromatic aberration and improve … be expected to disproportionately affect visual acuity with the …

[HTML][HTML] In vitro comparative optical bench analysis of a spherical and aspheric optic design of the same IOL model

T Tandogan, GU Auffarth, CY Choi, S Liebing… - BMC …, 2017 - Springer
effect of aspheric IOLs on patients’ visual functions [4–… conditions: from corneal spherical
aberrations to aperture sizes corresponding with pupil sizes at photopic and mesopic conditions

Clinical outcome and higher order aberrations after bilateral implantation of an extended depth of focus intraocular lens

D Pilger, D Homburg, T Brockmann… - European journal of …, 2018 - journals.sagepub.com
Visual acuity under photopic conditions at far (5 m), … Low-contrast visual acuity was tested
under mesopic conditions. The … Measurement of chromatic aberrations, however, was not a …

[HTML][HTML] Mesopic visual quality after accelerated corneal cross linking: A 12-month follow-up study

H Hashemi, S Asgari - Journal of Current Ophthalmology, 2017 - Elsevier
… Since the quality of vision and visual function are important … effect of accelerated CXL (18
mW/cm 2 , 5 min) on mesopic … , trefoil, spherical aberration (SA), and total HOAs were evaluated …

Changes in peripheral refraction, higher-order aberrations, and accommodative lag with a radial refractive gradient contact lens in young myopes

J Pauné, S Thivent, J Armengol, L Quevedo… - Eye & contact …, 2016 - journals.lww.com
… Other HOAs, especially spherical aberration (SA), have been … under photopic (105 cd/m 2
) and low mesopic (0.6 cd/m 2 ) … the visual acuity was measured under photopic conditions