[PDF][PDF] Influence of the irradiation geometry on the severity of acute radiation damage

VY Golikov, AV Vodovatov - РАДИАЦИОННАЯ ГИГИЕНА, 2022 - core.ac.uk
… with sealed sources of gamma radiation doses of emergency … located near the radiation
source – when wearing the source … of an effective dose when the 137Cs point source located at …

Simulating NEMA characteristics of the modular total-body J-PET scanner—an economic total-body PET from plastic scintillators

P Moskal, P Kowalski, RY Shopa… - Physics in Medicine …, 2021 - iopscience.iop.org
… , for 140 cm long tomograph and the point source placed in … locations (x = 1 cm, 10 cm and
20 cm) and two axial—at the … source of back-to-back gamma photons with length of 70 cm was …

AAPM TG 158: measurement and calculation of doses outside the treated volume from external‐beam radiation therapy

SF Kry, B Bednarz, RM Howell, L Dauer… - Medical …, 2017 - Wiley Online Library
… Data series with markers are from 10 cm × 10 cm fields and … Because Gamma Knife units
have a relatively low-energy … effective dose was found to be dominated by the therapeutic …

A sparse equivalent source method for near-field acoustic holography

E Fernandez-Grande, A Xenaki… - The Journal of the …, 2017 - pubs.aip.org
… is placed 10 cm away from the array (z h = 10 cm) and … takes place at 6 cm away from the
source (z s = 6 cm), thus … , it is the body of the guitar that radiates most effectively. The estimated …

[HTML][HTML] A simulation study of the system characteristics for a long axial FOV PET design based on monolithic BGO flat panels compared with a pixelated LSO …

M Dadgar, J Maebe, M Abi Akl, B Vervenne… - EJNMMI physics, 2023 - Springer
… We know the exact interaction point of the gamma photons … at the center of each scanner, as
well as offset by 10 cm in … the spatial resolution for point sources getting closer to the panels (…

Assessment of radioactivity of the Sobirsoy reservoir and adjacent areas of the Nurabad district, Uzbekistan

U Tukhtaev, S Khasanov, A Safarov, R Proshad - Radiochimica Acta, 2023 - degruyter.com
Before use, the PRSD was degassed in a drying chamber for … placed on a wire with a special
base, at a height of 10 cm … the absorbed gamma dose, annual effective dose rate, gamma

J-PET: a new technology for the whole-body PET imaging

S Niedźwiecki, P Białas, C Curceanu… - arXiv preprint arXiv …, 2017 - arxiv.org
… reduce the scattering of gamma quanta in the body of a patient … Test setup consisted of 22Na
source placed inside lead … TOF spectrum for one module from the second layer before- (left…

Tolerance limits and methodologies for IMRT measurement‐based verification QA: Recommendations of AAPM Task Group No. 218

M Miften, A Olch, D Mihailidis, J Moran… - Medical …, 2018 - Wiley Online Library
… that the evaluated dose point closest to the reference point is … dose (eg, 10 × 10 cm 2 at
reference depth) in phantom. … that increases the total body dose. Inverse planning methods are …

System characteristics comparison of the Walk-Through Total-Body PET and the Biograph Vision Quadra PET/CT

M Dadgar, J Maebe, M Abi Akl, B Vervenne… - 2023 - researchsquare.com
… reconstruct points (for spatial resolution measurements) near … , a 70 cm long line source
(back-to-back gamma emitter) with … placed at the center of each scanner, as well as offset by 10

A comprehensive experimental characterization of the iPIX gamma imager

K Amgarou, V Paradiso, A Patoz, F Bonnet… - Journal of …, 2016 - iopscience.iop.org
… in 1952 as a human body tomographic scanner to detect early … These sources were placed
on a horizontal line at 40 cm … when they are very close to each other (ie, ±6◦ separation angle…