DM Band and T. Treasure
EC Design, GM Read-out - Ion Selective Electrode Method …, 2018 - books.google.com
… One hospital had an automatic analyzer under trial. This had … In contact with hypertonic
bridge solutions, the cells crenate … We occasionally flush the salt bridge in the reference lumen. …
bridge solutions, the cells crenate … We occasionally flush the salt bridge in the reference lumen. …
Wearable sweatband sensor platform based on gold nanodendrite array as efficient solid contact of ion-selective electrode
… reference electrode containing 1 M LiAcO as ionic salt bridge. … of dehydration (hypertonic,
hypotonic, and isotonic dehydration)… the sweatband coupled with an electrochemical analyzer. …
hypotonic, and isotonic dehydration)… the sweatband coupled with an electrochemical analyzer. …
Reference electrodes with polymer-based membranes—Comprehensive performance characteristics
P Lingenfelter, B Bartoszewicz, J Migdalski, T Sokalski… - Membranes, 2019 - mdpi.com
… some electrolytic contact via the salt bridge. To minimize the … Such bridges, called hypertonic
in biological research, have … anyone having any experience with ion-selective electrodes. …
in biological research, have … anyone having any experience with ion-selective electrodes. …
Reference electrodes based on ionic liquid-doped reference membranes with biocompatible silicone matrixes
… Ion-selective electrodes (ISEs) are of great interest in the context … electrodes used in
potentiometry, such as the well-known Ag/AgCl electrode, contact the sample through a salt bridge …
potentiometry, such as the well-known Ag/AgCl electrode, contact the sample through a salt bridge …
Blood Gases Technical Aspects and Interpretation
C Travers, N Ambalavanan - … -E-BOOk: An Evidence-Based …, 2021 - books.google.com
… , analyzers use technologies such as potentiometry, amperometry, fluorescence, and ion-selective
electrodes … A double-blind, randomized, clinical trial comparing an isotonic amino acid …
electrodes … A double-blind, randomized, clinical trial comparing an isotonic amino acid …
High-Throughput Automated Patch Clamp Investigations on Ion Channels in Erythrocytes
MG Rotordam - 2021 - publikationen.sulb.uni-saarland.de
… Increased MCHC and consequent increased cytoplasmic viscosity may occur in aged cells,
in hypertonic conditions as a result of water loss or in pathological conditions as hereditary …
in hypertonic conditions as a result of water loss or in pathological conditions as hereditary …
Blood gases: Technical aspects and interpretation
Y Rabi, D Kowal, N Ambalavanan - … Based Approach to Newborn …, 2016 - books.google.com
… ion-selective electrodes are utilized to measure blood gases, electrolytes, and metabolites.
106 The analyzer … A double-blind, randomized, clinical trial comparing an isotonic amino acid …
106 The analyzer … A double-blind, randomized, clinical trial comparing an isotonic amino acid …
Nasal mucus: friend or foe? The effect of mucus on mucosal barrier dysfunction in chronic rhinosinusitis
SST Kao - 2020 - digital.library.adelaide.edu.au
Chronic rhinosinusitis (CRS) is a complex and heterogenous disease characterised by
nasal obstruction, facial pressure, rhinorrhoea, postnasal drip and reduction in smell. The …
nasal obstruction, facial pressure, rhinorrhoea, postnasal drip and reduction in smell. The …
Controlled drug delivery systems based on mesoporus silica and erythrocyte membranes
KS Bukara - Универзитет у Београду, 2017 - nardus.mpn.gov.rs
… Though some variability in the data, this formulation was promising to be further investigated
in a clinical trial setting. Subsequent clinical trial was conducted to assess the bioavailability…
in a clinical trial setting. Subsequent clinical trial was conducted to assess the bioavailability…