[HTML][HTML] Clinical validation of a population-based input function for 20-min dynamic whole-body 18F-FDG multiparametric PET imaging

AH Dias, AM Smith, V Shah, D Pigg, LC Gormsen… - EJNMMI physics, 2022 - Springer
… was scaled to the aorta image-derived input function (IDIF) to … lie still for 120 min while in
the PET/CT scanner and agreed … Underscoring the robustness of the image-derived approach, …

[HTML][HTML] Image quantification for TSPO PET with a novel image-derived input function method

YHD Fang, JE McConathy, TA Yacoubian, Y Zhang… - Diagnostics, 2022 - mdpi.com
18 F-DPA-714 in the human brain through dynamic PET scans. … Current methods for extracting
IDIF are usually based on … cohorts as an initial validation for this method and showed that …

[HTML][HTML] Population-based input function (PBIF) applied to dynamic whole-body 68Ga-DOTATOC-PET/CT acquisition

P Thuillier, D Bourhis, M Pavoine, JP Metges… - Frontiers in Nuclear …, 2022 - frontiersin.org
… model was built from 20 image-derived input functions (IDIFs) … approach allows for reduction
in WBdyn DOTATOC-PET/CT … 68Ga-DOTATOC-PET/CT and to validate its clinical use by …

[HTML][HTML] Validation of image-derived input function using a long axial field of view PET/CT scanner for two different tracers

X Palard-Novello, D Visser, N Tolboom, CLC Smith… - EJNMMI physics, 2024 - Springer
… Some authors developed correction methods to mitigate the impact of these effects on
quantification [… For [ 18 F]DPA-714 PET, the 60-min dynamic imaging data were binned into …

Machine learning derived input-function in a dynamic 18F-FDG PET study of mice

S Kuttner, KK Wickstrøm, G Kalda… - Biomedical Physics …, 2020 - iopscience.iop.org
… -derived input-function (MLDIF) with an image-derived AIF … -of-view of the PET/CT scanner,
lying on a 35 C heated bed … (5)), it remains to validate that MLDIF can explicitly account for …

[HTML][HTML] Assessment of population-based input functions for Patlak imaging of whole body dynamic 18F-FDG PET

M Naganawa, JD Gallezot, V Shah, T Mulnix, C Young… - EJNMMI physics, 2020 - Springer
… two methods: (1) the AUC of the image-derived input function (IDIF) and (2) the estimated
C P *(0). The aim of this study was to validate … for 90 min on a 4-ring Biograph mCT PET/CT

[HTML][HTML] An update on the use of image-derived input functions for human PET studies: new hopes or old illusions?

T Volpi, L Maccioni, M Colpo, G Debiasi, A Capotosti… - EJNMMI research, 2023 - Springer
… typically require long dynamic acquisitions (60120 min) to … by Siemens for clinical PET/CT
scanners with limited FOV (eg… the current scenario is that IDIF validation studies in the brain …

[HTML][HTML] Validation of a combined image derived input function and venous sampling approach for the quantification of [18F] GE-179 PET binding in the brain

M Galovic, K Erlandsson, TD Fryer, YT Hong… - Neuroimage, 2021 - Elsevier
… the PET/CT scanner. The fraction of parent tracer in plasma for 6 arterial plasma samples
(4.5, 10, … Dynamic PET images were corrected for head motion using a post-hoc frame-to-frame …

[HTML][HTML] Clinical application of a population-based input function (PBIF) for a shortened dynamic whole-body FDG-PET/CT protocol in patients with metastatic …

M Pavoine, P Thuillier, N Karakatsanis, D Legoupil… - EJNMMI physics, 2023 - Springer
… (FDG-PET/CT) is a functional imaging technique that can be … First, the use of an image-derived
input function (IDIF) has … clinically validated a shortened duration WB FDG-PET/CT

[HTML][HTML] Validation of cardiac image-derived input functions for functional PET quantification

MB Reed, PA Handschuh, C Schmidt, M Murgaš… - European Journal of …, 2024 - Springer
dynamic PET provides more robust outcome parameters [11,… techniques still rely on measuring
the arterial input function (… Next-generation PET/CT scanners exhibit improved spatial and …