[HTML][HTML] Plasmonic optical biosensors for detecting c-reactive protein: A review

JS Seok, H Ju - Micromachines, 2020 - mdpi.com
… CRP has a pentameric structure of the five identical … , and the sandwich assay modified
with metal nanoparticles or … the surface plasmon resonance (SPR)-based C-reactive protein (…

Bioanalytical advances in assays for C-reactive protein

SK Vashist, AG Venkatesh, EM Schneider… - Biotechnology …, 2016 - Elsevier
… The pCRP can be modified to monomeric CRP and even smaller peptides … pentameric and
monomeric CRPs using various capture monoclonal Abs that bind specifically to pentameric, …

Enhanced resolution of a surface plasmon resonance sensor detecting C-reactive protein via a bimetallic waveguide-coupled mode approach

HS Lee, TY Seong, WM Kim, I Kim, GW Hwang… - Sensors and Actuators B …, 2018 - Elsevier
… the resolution of surface plasmon resonance (SPR) sensors … waveguide-coupled surface
plasmon resonance (Bi-WCSPR) … Bi-WCSPR sensors used to detect C-reactive protein (CRP), …

[HTML][HTML] Oriented Antibody Covalent Immobilization for Label-Free Impedimetric Detection of C-Reactive Protein via Direct and Sandwich Immunoassays

A Adesina, P Mashazi - Frontiers in Chemistry, 2021 - frontiersin.org
… for the detection of C-reactive protein (CRP). The gold electrode modified with boronic
acid–terminated … This antibody-modified surface was able to capture human CRP protein, and the …

Online regeneration of a piezoelectric and impedimetric immunosensor for the detection of C-reactive protein on the oriented antibody gold surface

A Adesina, O Adeniyi, P Mashazi - Analytical Methods, 2023 - pubs.rsc.org
… In addition, CRP is a pentameric protein with several binding sites for the antibodies, thus …
for the C-reactive protein using a screen-printed carbon electrode modified with graphene and …

Gold nanoparticles-enhanced gold-silver alloy surface plasmon resonance sensor for the detection of C-reactive protein

R Yi, Z Zhang, C Liu, Z Qi - European Conference on Biomedical …, 2019 - opg.optica.org
… interactions with C-reactive protein using a surface plasmon resonance biosensor[J]. …
Immunodetection of pentamer and modified C-reactive protein using surface plasmon resonance

Application of hybrid Au@ Ag nanostructures in fiber optic biosensor for rapid detection of C-reactive protein

NTT Phuong, NHN Thao, HKT Ta, NQM Tran, TN Bach… - Optical Materials, 2023 - Elsevier
… material for optical fiber sensor application to sensitively monitor C-reactive protein
Immunodetection of pentamer and modified C-reactive protein using surface plasmon resonance

[HTML][HTML] Diagnoses based on C-reactive protein point-of-care tests

M Pohanka - Biosensors, 2022 - mdpi.com
… the common pentameric form of CRP or total CRP not distinguishing monomeric and …
resonance sensor chip was modified by protein A and albumin was used for saturating the surface

Ionic strength-sensitive and pH-insensitive interactions between C-reactive protein (CRP) and an anti-CRP antibody

Y Oka, S Ushiba, N Miyakawa, M Nishio… - Biophysics and …, 2022 - jstage.jst.go.jp
C-reactive protein (CRP) is regarded as a universal biomarker … using field-effect transistors
(FETs) [8], surface plasmon … , as many factors may modify the binding properties. Therefore, it …

Fast label-free detection of C-reactive protein using broad-band Mach-Zehnder interferometers integrated on silicon chips

A Psarouli, A Botsialas, A Salapatas, G Stefanitsis… - Talanta, 2017 - Elsevier
… , such as surface plasmon resonance (… proteins was attempted through modification with
APTES or GOPTS. Effective silanization requires cleaning and hydrophilization of the surfaces