[HTML][HTML] Useful measures and models for analytical quality management in medical laboratories
JO Westgard - Clinical Chemistry and Laboratory Medicine (CCLM), 2016 - degruyter.com
… examination variables, such as sampling variation, sampling … bias can be eliminated or
completely corrected is not valid for … perhaps our most standardized examination procedure today…
completely corrected is not valid for … perhaps our most standardized examination procedure today…
[PDF][PDF] Six Sigma Metrics: An Evolving Indicator of Quality Assurance for Clinical Biochemistry
DP PRADHAN, D PANDIT, S SAHOO… - … & Diagnostic Research, 2022 - academia.edu
… Six Sigma quality management methodology has attracted … 2] illustrated the calculated
Bias% and sigma matrices of each … and Triglyceride) and Cholesterol had both inaccuracy and …
Bias% and sigma matrices of each … and Triglyceride) and Cholesterol had both inaccuracy and …
[HTML][HTML] Best practices for the design, laboratory analysis, and reporting of trials involving fatty acids
… plasma PL measurements can be a biased view of the fatty acid … of cholesterol than serum
because of an osmotic effect of the … method should use proper quality control (QC) techniques …
because of an osmotic effect of the … method should use proper quality control (QC) techniques …
Quality control
WG Miller, JH Nichols - Contemporary Practice in Clinical Chemistry, 2020 - Elsevier
… is sensitive to large systematic bias, the 2 2S component is sensitive to systematic bias, and
the R 4S … Matrix effects on proficiency testing materials: impact on accuracy of cholesterol …
the R 4S … Matrix effects on proficiency testing materials: impact on accuracy of cholesterol …
Enhancing the accuracy of measurement of small molecule organic biomarkers
TL Teo, KA Lippa, L Mackay, S Yong, Q Liu… - Analytical and …, 2019 - Springer
… nation’s quality control system for cholesterol measurement. By … of cholesterol esters may
have contributed to biases in the … for accurate diagnosis, treatment or dosage adjustments. …
have contributed to biases in the … for accurate diagnosis, treatment or dosage adjustments. …
Mendelian randomization
… We give examples of a range of studies in which MR has … Finally, we outline sources of bias
that may affect MR studies … expected owing to sampling error, then at least one is not valid for …
that may affect MR studies … expected owing to sampling error, then at least one is not valid for …
[PDF][PDF] Matrix Effect in Chemotherapy Patients
HB Yavuz - MEDICAL BIOCHEMISTRY, 2018 - jag.journalagent.com
… Bias and variation coefficient were calculated external … , in at least one internal quality control
sample, sigma values were … While creatinine, glucose, total protein, K, total cholesterol had …
sample, sigma values were … While creatinine, glucose, total protein, K, total cholesterol had …
[HTML][HTML] The new diagnosis-related group reimbursement system and laboratory test quality in Korea: analysis of external quality assessment results
S Kim, YM Yun, H Kim, TH Um, J Chang, H Jeong… - Healthcare, 2020 - mdpi.com
… the same methods, since it is expected that each method will … to assess bias in performance
between CASE and control groups… For example, test quality may be positively affected by the …
between CASE and control groups… For example, test quality may be positively affected by the …
[HTML][HTML] A quantitative LC-MS/MS method for analysis of mitochondrial-specific oxysterol metabolism
… to maintain cholesterol/oxysterol homeostasis. Here we describe a … samples were used
as the quality control for the analyses. … factors and bias for validation studies and biomarker …
as the quality control for the analyses. … factors and bias for validation studies and biomarker …
[图书][B] Establishment of a stable microbiology external quality control matrix in transfusion medicine
XL Mpumlwana - 2021 - search.proquest.com
… A prospective cross-sectional approach was used in this study … and 11 RCPCA PT samples
were evaluated for cholesterol … A matrix effect with a minimal bias was noted on the RCPA …
were evaluated for cholesterol … A matrix effect with a minimal bias was noted on the RCPA …