[HTML][HTML] Useful measures and models for analytical quality management in medical laboratories

JO Westgard - Clinical Chemistry and Laboratory Medicine (CCLM), 2016 - degruyter.com
examination variables, such as sampling variation, samplingbias can be eliminated or
completely corrected is not valid for … perhaps our most standardized examination procedure today…

[PDF][PDF] Six Sigma Metrics: An Evolving Indicator of Quality Assurance for Clinical Biochemistry

DP PRADHAN, D PANDIT, S SAHOO… - … & Diagnostic Research, 2022 - academia.edu
… Six Sigma quality management methodology has attracted … 2] illustrated the calculated
Bias% and sigma matrices of each … and Triglyceride) and Cholesterol had both inaccuracy and …

[HTML][HTML] Best practices for the design, laboratory analysis, and reporting of trials involving fatty acids

JT Brenna, M Plourde, KD Stark, PJ Jones… - The American journal of …, 2018 - Elsevier
… plasma PL measurements can be a biased view of the fatty acid … of cholesterol than serum
because of an osmotic effect of the … method should use proper quality control (QC) techniques

Quality control

WG Miller, JH Nichols - Contemporary Practice in Clinical Chemistry, 2020 - Elsevier
… is sensitive to large systematic bias, the 2 2S component is sensitive to systematic bias, and
the R 4S … Matrix effects on proficiency testing materials: impact on accuracy of cholesterol

Enhancing the accuracy of measurement of small molecule organic biomarkers

TL Teo, KA Lippa, L Mackay, S Yong, Q Liu… - Analytical and …, 2019 - Springer
… nation’s quality control system for cholesterol measurement. By … of cholesterol esters may
have contributed to biases in the … for accurate diagnosis, treatment or dosage adjustments. …

Mendelian randomization

E Sanderson, MM Glymour, MV Holmes… - … Reviews Methods …, 2022 - nature.com
… We give examples of a range of studies in which MR has … Finally, we outline sources of bias
that may affect MR studies … expected owing to sampling error, then at least one is not valid for …

[PDF][PDF] Matrix Effect in Chemotherapy Patients

HB Yavuz - MEDICAL BIOCHEMISTRY, 2018 - jag.journalagent.com
Bias and variation coefficient were calculated external … , in at least one internal quality control
sample, sigma values were … While creatinine, glucose, total protein, K, total cholesterol had …

[HTML][HTML] The new diagnosis-related group reimbursement system and laboratory test quality in Korea: analysis of external quality assessment results

S Kim, YM Yun, H Kim, TH Um, J Chang, H Jeong… - Healthcare, 2020 - mdpi.com
… the same methods, since it is expected that each method will … to assess bias in performance
between CASE and control groups… For example, test quality may be positively affected by the …

[HTML][HTML] A quantitative LC-MS/MS method for analysis of mitochondrial-specific oxysterol metabolism

K Borah, OJ Rickman, N Voutsina, I Ampong, D Gao… - Redox biology, 2020 - Elsevier
… to maintain cholesterol/oxysterol homeostasis. Here we describe a … samples were used
as the quality control for the analyses. … factors and bias for validation studies and biomarker …

[图书][B] Establishment of a stable microbiology external quality control matrix in transfusion medicine

XL Mpumlwana - 2021 - search.proquest.com
… A prospective cross-sectional approach was used in this study … and 11 RCPCA PT samples
were evaluated for cholesterol … A matrix effect with a minimal bias was noted on the RCPA …