Line field optical coherence tomography
… The line field (LF) design choice for the lateral image formation mechanism (lateral format)
has historically been a fraction of the whole optical coherence tomography (OCT) field. …
has historically been a fraction of the whole optical coherence tomography (OCT) field. …
Line field Fourier domain optical coherence tomography based on a spatial light modulator
… In this study, we developed a line-field Fourier domain optical coherence tomography (LF-FDOCT)
system that performs lateral scanning using a two-dimension spatial light modulator …
system that performs lateral scanning using a two-dimension spatial light modulator …
[PDF][PDF] Line Field Optical Coherence Tomography. Photonics 2022, 9, 946
… Abstract: The line field (LF) design choice for the lateral image formation mechanism (lateral
format) has historically been a fraction of the whole optical coherence tomography (OCT) …
format) has historically been a fraction of the whole optical coherence tomography (OCT) …
Line-field swept-source interferometer for simultaneous measurement of thickness and refractive index distribution
… Recently, we have suggested that a swept source of approximately 800 nm … -source
optical coherence tomography (SS-OCT) [18], [19] and spectroscopic OCT [20] when the line-field …
optical coherence tomography (SS-OCT) [18], [19] and spectroscopic OCT [20] when the line-field …
Swept-source optical coherence tomography by off-axis Fresnel transform digital holography with an output throughput of 10 Giga voxels per second in real-time
E Charpentier, F Lapeyre, J Gautier… - arXiv preprint arXiv …, 2020 - arxiv.org
… Line-field OCT is a hybrid method, benefiting from the advantages of confocal and full field
detection schemes, while suffering from … by frequency sweeping digital holography. Applied …
detection schemes, while suffering from … by frequency sweeping digital holography. Applied …
Scanless Optical Coherence Tomography for High-Speed 3D Biomedical Microscopy
Y Wang - 2020 - search.proquest.com
… optically computed optical coherence tomography (OC-OCT), and the other approach is
Line field … Frequency-Sweeping Source 50 5.1 The configuration of the LF-FDOCT system…………
Line field … Frequency-Sweeping Source 50 5.1 The configuration of the LF-FDOCT system…………
Digital adaptive optics based on digital lateral shearing of the computed pupil field for point scanning retinal swept source OCT
A Kumar, S Georgiev, M Salas… - Biomedical Optics …, 2021 - opg.optica.org
… flying spot time domain (TD) OCT, line field spectral domain (LF SD) OCT or … using a
broadband light source and a spectrometer, or temporally by frequency sweeping the laser source…
broadband light source and a spectrometer, or temporally by frequency sweeping the laser source…
Enhanced medical diagnosis for dOCTors: a perspective of optical coherence tomography
… retinal line-field imaging, using B-scan rates of several kHz 43 has been recommended to
avoid axial blurring. Recently, a high-speed CMOS camera has been applied for fast line field …
avoid axial blurring. Recently, a high-speed CMOS camera has been applied for fast line field …
Wavelength-swept fiber laser based on acousto-optic tuning method
M Chen, Y Fan, H Zhang, J Tao… - Optics in Health Care …, 2016 - spiedigitallibrary.org
… The laser output is from another port of the fiber coupler. The laser made by this method is
mainly used for swept-source optical coherence tomography(SS-OCT). The application of the …
mainly used for swept-source optical coherence tomography(SS-OCT). The application of the …
An imaging system integrating optical coherence tomography and interferometry for in vivo measurement of the thickness and dynamics of the tear film
… We developed a system that combines simultaneous optical coherence tomography (OCT)
and thickness dependent fringes (TDF) interferometry for in vivo imaging of the tear film. The …
and thickness dependent fringes (TDF) interferometry for in vivo imaging of the tear film. The …