18 F-FDG PET/MR imaging in patients with suspected liver lesions: Value of liver-specific contrast agent Gadobenate dimeglumine

J Kirchner, LM Sawicki, C Deuschl, J Grüneisen… - PloS one, 2017 - journals.plos.org
Objectives To evaluate the added value of the application of the liver-specific contrast phase
of Gadobenate dimeglumine (Gd-BOPTA) for detection and characterization of liver lesions …

Effect of increasing the flip angle during the hepatocyte phase of gadobenate dimeglumine‐enhanced 1.5 T MRI in cirrhotic patients with hepatocellular carcinoma

EJ Lee, DJ Kim, ES Cho, KA Kim - … of Magnetic Resonance …, 2016 - Wiley Online Library
echo-planar imaging (EPI… image filters because of the inhomogeneous distribution of
noise.14 However, we believe our method for measuring noise in the “empty space” of the imaging

… ‐enhanced magnetic resonance imaging: Prospective randomized intraindividual comparison of gadoterate meglumine (0.15 mmol/kg) and gadobenate dimeglumine …

P Clauser, TH Helbich, P Kapetas… - … Resonance Imaging, 2019 - Wiley Online Library
gadopentetate dimeglumine (Magnevist; Bayer, Berlin, Germany) for breast MRI.10 This
dosage set-up for our breast MR imaging … The patient sample size was based on the primary …

… of gadolinium-based contrast agent concentrations (0.5 M or 1.0 M) on the diagnostic performance of magnetic resonance imaging examinations: systematic review of …

E Lancelot, J Froehlich, O Heine… - Acta Radiologica, 2016 - journals.sagepub.com
… observed under non-equimolar delivery rates. However, they … , volume, injection rate, saline
flush volume) and imaging … gadobutrol than with gadopentetate dimeglumine. The results of …

Effectiveness of a high relaxivity contrast agent administered at half dose in dynamic susceptibility contrast MRI of brain gliomas

G Crisi, S Filice, G Erb, F Bozzetti - … of Magnetic Resonance …, 2017 - Wiley Online Library
… Cerebral Blood Volume (CBV) measurements by means of … -0001 -weighted echo-planar
imaging during the first pass of a … of the approved dose of gadobenate dimeglumine (0.05 mmol/…

Comparison of the Ability of Gadobenate Dimeglumine and Gadolinium Ethoxybenzyl Dimeglumine to Display the major Features for Noninvasively Diagnosing …

WW Yao, HW Zhang, JM Lee, R Lee… - … in Cancer Research …, 2024 - journals.sagepub.com
… diffusion-weighted imaging with a single-shot echo-planar sequence with … measured
manually by 2 abdominal radiologists (with 16 and 6 years of experience in abdominal MR imaging

Diffusion-weighted imaging of the dentate nucleus after repeated application of gadolinium-based contrast agents in multiple sclerosis

P Eisele, K Szabo, A Ebert, A Radbruch… - Magnetic Resonance …, 2019 - Elsevier
… protocol included (1) diffusion-weighted echo planar [EP] … intravenous exposure a considerable
amount of gadolinium had … and better quantitative measurements of ADC values in the …

The potential toxic impact of different gadolinium-based contrast agents combined with 7-T MRI on isolated human lymphocytes

B Friebe, F Godenschweger, M Fatahi, O Speck… - European Radiology …, 2018 - Springer
… As the number of magnetic resonance imaging (MRI) … To increase potential toxic effects,
an echo planar imaging … the circumstances that only a limited amount of analyses could be …

Contrast agents in cardiovascular magnetic resonance imaging

DJ Murphy, RY Kwong - Cardiovascular Magnetic Resonance Imaging, 2019 - Springer
… ” protons per unit volume), inflow phenomena, … distribution, except for varying hepatocyte
uptake for certain agents (gadoxetate disodium/gadoxetic acid and gadobenate dimeglumine

Early gadolinium enhancement for determination of area at risk: a preclinical validation study

S Hammer-Hansen, SW Leung, LY Hsu… - … Cardiovascular Imaging, 2017 - jacc.org
… bolus of contrast (gadopentetate dimeglumine [Magnevist], … not contaminated by partial
volume errors with salvaged … myocardial oedema by magnetic resonance imaging early after …