[HTML][HTML] Antitachycardia pacing programming in implantable cardioverter defibrillator: a systematic review
E De Maria, D Giacopelli, A Borghi… - World journal of …, 2017 - ncbi.nlm.nih.gov
… in the treatment of ventricular arrhythmias, whether slow or fast. … With the increase in ICD
indications, the choice of an optimal … times, ATP therapies during capacitor charging turned on) …
indications, the choice of an optimal … times, ATP therapies during capacitor charging turned on) …
Shock reduction with antitachycardia pacing before and during charging for fast ventricular tachycardias in patients with implantable defibrillators
PD Dallaglio, I Anguera, JBM Ferrer, L Pérez… - Revista Española de …, 2018 - Elsevier
… fast ventricular tachycardias in the ventricular fibrillation zone in patients with an implantable
cardioverter-defibrillator … window, the optimization of ATP by programming bursts before and …
cardioverter-defibrillator … window, the optimization of ATP by programming bursts before and …
Efficacy and safety of appropriate shocks and antitachycardia pacing in transvenous and subcutaneous implantable defibrillators: analysis of all appropriate therapy in …
RE Knops, W Van Der Stuijt, PPHM Delnoy… - Circulation, 2022 - Am Heart Assoc
… for implantable cardioverter defibrillator (ICD) therapy. Patients … unsuccessful in terminating
ventricular arrhythmias, we … of ATP, and a shorter capacitor charge time of the TV-ICD. It is …
ventricular arrhythmias, we … of ATP, and a shorter capacitor charge time of the TV-ICD. It is …
Progressive implantable cardioverter-defibrillator therapies for ventricular tachycardia: The efficacy and safety of multiple bursts, ramps, and low-energy shocks
M Strik, FD Ramirez, N Welte, T Bonnin, S Abu-Alrub… - Heart Rhythm, 2020 - Elsevier
… on optimal implantable cardioverter-defibrillator programming … antitachycardia pacing (ATP)
for the treatment of ventricular … often treated with a burst of ATP before or during charging of …
for the treatment of ventricular … often treated with a burst of ATP before or during charging of …
Novel implantable cardioverter defibrillator programming with high rate cut-off, long detection intervals and multiple anti-tachycardia pacing reduces mortality
AD Schober, AL Schober, U Hubauer… - Circulation …, 2021 - jstage.jst.go.jp
… charging followed by shock therapies. The detection time … ICD therapies to life-threatening
ventricular arrhythmias and to … are still warranted to optimize ICD programming. Randomized …
ventricular arrhythmias and to … are still warranted to optimize ICD programming. Randomized …
Management of implantable cardioverter defibrillator recipients: care beyond guidelines
F Philippon, LD Sterns, PB Nery, R Parkash… - Canadian Journal of …, 2017 - Elsevier
… received an ICD for ventricular arrhythmias (secondary prevention ICD … Optimizing the
arrhythmia rate when device therapy is triggered is … Programming antitachycardia pacing therapies …
arrhythmia rate when device therapy is triggered is … Programming antitachycardia pacing therapies …
Failure to treat life-threatening ventricular tachyarrhythmias in contemporary implantable cardioverter–defibrillators: Implications for strategic programming
AM Thøgersen, JM Larsen, JB Johansen… - … : Arrhythmia and …, 2017 - Am Heart Assoc
… restrict therapy to regular rhythms in ventricular tachycardia … prevention for implantable
cardioverter–defibrillator (ICD), 2 … initiating VT because antitachycardia pacing slowed the VT to …
cardioverter–defibrillator (ICD), 2 … initiating VT because antitachycardia pacing slowed the VT to …
Different impact of long-detection interval and anti-tachycardia pacing in reducing unnecessary shocks: data from the ADVANCE III trial
A Arenal, A Proclemer, A Kloppe, M Lunati… - EP …, 2016 - academic.oup.com
… patients at high risk of ventricular arrhythmias. However, ICD … detection and ATP during
charge can optimize the reduction … on optimal implantable cardioverter-defibrillator programming …
charge can optimize the reduction … on optimal implantable cardioverter-defibrillator programming …
Additional antitachycardia pacing programming strategies further reduce unnecessary implantable cardioverter-defibrillator shocks
… used, and 1 ATP sequence during charging in the VF zone. The … the initial therapy at
terminating fast ventricular arrhythmias (75… pacing pulses, must also be considered when …
terminating fast ventricular arrhythmias (75… pacing pulses, must also be considered when …
[HTML][HTML] Automatic adjustment of ventricular antitachycardia pacing and individualized device therapy
R Tripathi, C Gubran, C Jeavons - HeartRhythm Case Reports, 2022 - Elsevier
… of iATP prior to and during charging, followed by full-output (40 … the successful conversion of
ventricular tachycardia to sinus … ramp overdrive pacing for both slow (<188 bpm) and fast VT. …
ventricular tachycardia to sinus … ramp overdrive pacing for both slow (<188 bpm) and fast VT. …