Physiological closed-loop control in intelligent oxygen therapy: A review

D Sanchez-Morillo, O Olaby… - Computer methods and …, 2017 - Elsevier
… a simulated method for automatically regulating the oxygen … An oximeter used as a sensor
in an intelligent oxygen therapy … the importance of adequate oxygen flow control to avoid …

Applying computer models to realize closed-loop neonatal oxygen therapy

E Morozoff, JA Smyth, M Saif - Anesthesia & Analgesia, 2017 - journals.lww.com
modeling the system’s components: the oxygen transport within the patient, the oxygen blender,
the controller, and the pulse oximeter… Astrup’s 7 historical review of pulse oximeters, they …

Plug-and-Play Oxygen Auto-flow Regulator for Low Flow Oxygen Therapy: A Prototype Development

M Balasubramanian, AB Pattaje… - 2022 IEEE …, 2022 - ieeexplore.ieee.org
oxygen tank, pressure regulator and specialized oxygen … based oxygen flow controller suitable
for low flow oxygen therapyOximetry feedback flow control simulation for oxygen therapy.…

Automated Oxygen Blender for Regulation of Oxygen Saturation in Hypoxia Patient

S Anikhindi, S Patil, P Kaushal - Communication and Intelligent Systems …, 2022 - Springer
feedback control system was simulated at different oxygenoximeter to maintain a target SpO
2 of 91% by regulating the … compared to the fixed flow rate long-term oxygen therapy (LTOT)…

Clinical evaluation of a novel adaptive algorithm for automated control of oxygen therapy in preterm infants on non-invasive respiratory support

GK Plottier, KI Wheeler, SKM Ali, OS Fathabadi… - Archives of Disease in …, 2017 - fn.bmj.com
oxygen control using a standalone device, receiving SpO 2 input from a standard oximeter
and computing alterations to oxygen … In preclinical testing using simulation, this algorithm has …

Automated oxygen control in preterm infants, how does it work and what to expect: a narrative review

HH Salverda, SJE Cramer, RSGM Witlox… - Archives of Disease in …, 2021 - fn.bmj.com
use oxygen saturation as measured by pulse oximetry (SpO … reviews comparing AOC with
manual titration of oxygen in preterm infants receiving respiratory support and oxygen therapy. …

A randomized controlled trial of oxygen therapy for patients who do not respond to upper airway surgery for obstructive sleep apnea

SA Joosten, M Tan, AM Wong, SA Landry… - Journal of Clinical …, 2021 - jcsm.aasm.org
… stability/instability of a feedback loop system. In a ventilatory … plethysmography bands,
and fingertip pulse oximetry. … Grael amplifier and a wall-mounted oxygen/air flow regulator. …

Efficiency of different flows for apneic oxygenation when using high flow nasal oxygen application–a technical simulation

WA Wetsch, H Herff, DC Schroeder, D Sander… - BMC …, 2021 - Springer
… a paramagnetic oximeter that was … flow nasal oxygen therapy in COVID-19 patients at the
beginning of the pandemic. Thus, the lowest possible air flow that maintains adequate oxygen

Dose variability of supplemental oxygen therapy with open patient interfaces based on in vitro measurements using a physiologically realistic upper airway model

I Katz, J Chen, K Duong, K Zhu, M Pichelin… - Respiratory …, 2019 - Springer
… rate due to variation in simulated breathing pattern. Among the … oxygen cylinder through a
calibrated mass flow controller (… The oxygen saturation should be checked by pulse oximetry in …

Comparison of pulsed versus continuous oxygen delivery using realistic adult nasal airway replicas

JZ Chen, IM Katz, M Pichelin, K Zhu… - … journal of chronic …, 2017 - Taylor & Francis
… between SF and PF oxygen administration from POCs using … for alveolar oxygen uptake
in the lung simulator used in this … for reviewing and providing helpful comments on an earlier …