Temporal incidence of appropriate and inappropriate therapy and mortality in secondary prevention ICD patients by cardiac diagnosis
… the mainstay of prevention of sudden cardiac death during … reduction in appropriate ICD
therapies was observed in the period from 2000 to 2015 among patients with primary preventive …
therapies was observed in the period from 2000 to 2015 among patients with primary preventive …
Primary prevention of sudden cardiac death with implantable cardioverter-defibrillator therapy in patients with arrhythmogenic right ventricular cardiomyopathy
…, KH Haugaa, H Bundgaard, A Svensson… - … journal of cardiology, 2019 - Elsevier
… defined as reduced left … Inappropriate ICD shocks were seen in 24 patients and occurred
with similar 10-year cumulative incidence in patients from primary vs secondary prevention …
with similar 10-year cumulative incidence in patients from primary vs secondary prevention …
[HTML][HTML] ICD therapy for primary prevention in hypertrophic cardiomyopathy
A Trivedi, BP Knight - Arrhythmia & electrophysiology review, 2016 - ncbi.nlm.nih.gov
… an individual’s risk of sudden cardiac death (SCD). This review … reduction in inappropriate
ICD therapy. The authors found that 20 % of patients in the cohort were treated inappropriately …
ICD therapy. The authors found that 20 % of patients in the cohort were treated inappropriately …
Prevention of sudden death in heart failure with reduced ejection fraction: do we still need an implantable cardioverter‐defibrillator for primary prevention?
…, T Ben Gal, A Ristic, A Rakisheva… - … Journal of Heart …, 2022 - Wiley Online Library
… optimal use of disease-modifying therapies (BB, MRA, ARNI … inappropriate shocks and device
malfunction that lead, in some … the primary prevention of sudden cardiac death in patients …
malfunction that lead, in some … the primary prevention of sudden cardiac death in patients …
Device therapies among patients receiving primary prevention implantable cardioverter‐defibrillators in the Cardiovascular research network
…, SC Hammill, JJ Hayes, A Kadish… - … of the American Heart …, 2018 - Am Heart Assoc
… ‐defibrillator for primary prevention of sudden cardiac death, … (ICDs) reduce risk of death as
a primary prevention strategy. … Inappropriate ICD therapies are associated with subsequent …
a primary prevention strategy. … Inappropriate ICD therapies are associated with subsequent …
Improving the appropriateness of sudden arrhythmic death primary prevention by implantable cardioverter-defibrillator therapy in patients with low left ventricular …
…, G Casolo, P Delise, A Di Lenarda… - … of Cardiovascular …, 2016 - journals.lww.com
… The randomized Sudden Cardiac Death in Heart Failure … for ICD implantation for primary
prevention of sudden … a reduction in mortality among patients undergoing ICD implantation …
prevention of sudden … a reduction in mortality among patients undergoing ICD implantation …
… implications of appropriate implantable cardioverter defibrillator therapy in secondary prevention patients: contrasting mortality in primary prevention patients from a …
F Almehmadi, A Porta‐Sánchez, ACT Ha… - … of the American Heart …, 2017 - Am Heart Assoc
… (ICD) are the mainstay for preventing sudden cardiac death in patients with structural heart
… Inappropriate ICD therapies and the specific type of mortality were not analyzed in our study …
… Inappropriate ICD therapies and the specific type of mortality were not analyzed in our study …
Primary prevention of sudden death in patients with valvular cardiomyopathy
M Rodríguez-Mañero, MT Barrio-López, EA Assi… - Revista Española de …, 2016 - Elsevier
… of patients can benefit from primary prevention with an ICD, similar to those with cardiomyopathy
… with valve diseases did not show a higher rate of inappropriate therapies than patients …
… with valve diseases did not show a higher rate of inappropriate therapies than patients …
Implantable cardioverter-defibrillator therapy among patients with non-ischaemic vs. ischaemic cardiomyopathy for primary prevention of sudden cardiac death
…, MC Perier, D Gras, V Algalarrondo, A Bouzeman… - EP …, 2018 - academic.oup.com
… ventricular arrhythmias and sudden cardiac death (SCD). … cardioverter defibrillator (ICD)
therapy to reduce risk of SCD and … and inappropriate ICD therapies. The first appropriate …
therapy to reduce risk of SCD and … and inappropriate ICD therapies. The first appropriate …
… dual‐chamber implantable cardioverter‐defibrillators for primary prevention of sudden cardiac death: results from the cardiovascular research network longitudinal …
…, AS Go, DJ Magid, A Cassidy‐Bushrow… - … of the American Heart …, 2017 - Am Heart Assoc
… in reducing inappropriate shocks among primary prevention recipients in … inappropriate
shocks, informing the selection of devices in patients undergoing primary prevention ICD therapy …
shocks, informing the selection of devices in patients undergoing primary prevention ICD therapy …