Metal versus poly ether-ether Ketone secondary copings for rigid telescopic retained implant supported mandibular over dentures. Evaluation of clinical retention …

A Emarah - Egyptian Dental Journal, 2020 - journals.ekb.eg
period, PEEK secondary copings for telescopic attachments … evaluating retention forces of
implant overdenture attachmentsOverdenture attachment selection and the loading of implant …

[HTML][HTML] Evaluation of the effects of oral rinses on the retention and surface topography of the ball attachment complex for implant overdentures

D Gopalakrishnan, AN Sivaprakasam, V Jeyapalan… - 2023 - jdir.org
… assemblies were transferred to prosthetic blocks using the directperiod of 15 minutes per
day, 45 hours immersion periodload 16) . This wear is due to friction between the base and …

Effects of Low-Profile Stud Attachment Configurations on Stress Distribution Characteristics of Implant-Retained Overdentures.

E Tokar, B Uludag - … Journal of Oral & Maxillofacial Implants, 2018 - search.ebscohost.com
… The researchers compared a stud attachment (ERA) and … In the present study, the loaded
side denture-bearing areas … overdentures on 2 implants: 6-month fatigue retention values. …

The effect of different water temperatures on retention loss and material degradation of locator attachments

LPY Chiu, ND Vitale, H Petridis… - Journal of …, 2017 - Wiley Online Library
… recently introduced implant overdenture attachment systems, … C, and cyclic loading for a
simulation period equivalent to 5 … and retention values of Locator attachments; therefore direct

The effect of number and distribution of mini dental implants on overdenture stability: an in vitro study

R Alshenaiber, C Barclay, N Silikas - Materials, 2022 - mdpi.com
… and retain overdenture was better accompanied by a sufficient residual ridge to share the load
[16… flow and temperature within the testing period. Moreover, some studies suggested that …

Effect of bar cross-section and female housing material on retention of mandibular implant bar overdentures: A comparative: in vitro: study

EA Abdel-Khalek, AM Ibrahim - The Journal of Indian …, 2017 - journals.lww.com
… Within the limitation of this in vitro study and for a similar period … processing, the plastic
clips were picked up directly on the … the peak load forces were measured in Newtons using a …

Long-Term Prosthetic Aftercare of Mandibular Implant-Supported Overdenture

E Zenziper, O Rosner, O Ghelfan, J Nissan, S Blumer… - Applied Sciences, 2022 - mdpi.com
… implants to support/retain a mandibular overdenture due to … time the denture is worn in the
mouth or loaded under function. … to the locator after an in vitro fatigue simulation period of 5.5 …

[PDF][PDF] AL-AZHAR

MA Eladrosi, HW Abozaed, MA ELsyad - Codex, 2023 - academia.edu
After 3 months of Osseo-integration period, a tissue punch was … overdenture that retained
by TITACH attachment with direct … Moreover, it allows for standardization of points of load

Retention force of removable partial dentures with CAD-CAM-fabricated telescopic crowns

C Arnold, R Schweyen, A Boeckler, J Hey - Materials, 2020 - mdpi.com
… artificial aging and after axial and non-axial loading. Initially [I… The primary crowns were
modelled in wax directly on the … a sufficient retention force is ensured over the tested period. It …

[图书][B] In Vitro Study of Retentive Properties of Different Overdenture Attachment Systems On Straight and Divergent Dental Implants

KA Azzouz - 2017 - search.proquest.com
… stability and retention of the denture due to impaired load-… Osseointegration: the apparent
direct attachment or connection … the retention of 4 different color-coded ERA attachments (…