The dependence of electrode impedance on the number of performed EEG examinations

J Górecka, P Makiewicz - Sensors, 2019 - mdpi.com
… In clinical practice, the scalp-electrode impedance is checked before each EEG … of impedance
analysis of new and used EEG electrodes obtained using the Electrochemical Impedance

Analysis of a low-cost EEG monitoring system and dry electrodes toward clinical use in the neonatal ICU

M O'Sullivan, A Temko, A Bocchino, C O'Mahony… - Sensors, 2019 - mdpi.com
electrodes have higher impedance than wet electrodes, causing a reduction in signal quality
, leaving the majority of the layer intact, thus reducing the risk of irritation or infection [42]. …

Contamination of reusable electroencephalography electrodes: A multicenter study

NM Albert, JF Bena, C Ciudad… - … Journal of Infection …, 2018 - Elsevier
… by risk for hospital-acquired infection: no risk, potential risk (… risk (associated with infections
and antibiotic resistance). At-… research, scalp infection was not assessed and EEG cleaning …

Cost-Effectiveness Analysis of Single-Use EEG Cup Electrodes Compared with Reusable EEG Cup Electrodes

A Sohrt, A Mærkedahl, WV Padula - PharmacoEconomics-Open, 2019 - Springer
… Before applying EEG-CE to the scalp, the skin is cleaned and … impedance level [6, 7]. Because
of this abrasion of the skin, … the risk of sepsis in this study, not the risk of minor infections

Comparison of a novel dry electrode headset to standard routine EEG in veterans

JJ Halford, RJ Schalkoff, KE Satterfield… - Journal of Clinical …, 2016 - journals.lww.com
… and an associated risk of infection if the electrodes are not … EEG electrode technology,
which relies on a low impedance … The lower signal quality of the last 10 minutes of the DES …

Comparison of a pragmatic and regression approach for wearable EEG signal quality assessment

J Witteveen, P Pradhapan… - IEEE journal of …, 2019 - ieeexplore.ieee.org
… Magnitude of electrical activity on the surface of the scalp is … relationship between contact
quality and signal quality is not … relation between signal quality and contact impedance. This …

Review of semi-dry electrodes for EEG recording

GL Li, JT Wu, YH Xia, QG He… - Journal of Neural …, 2020 - iopscience.iop.org
… The signal quality at the front end, where EEG electrodesScalp abrasion can introduce
the risk of infection and can be … The electrode/skin impedance and signal quality of solid-gel …

Preclinical safety study of a fully implantable, sub-scalp ring electrode array for long-term EEG recordings

YB Benovitski, A Lai, A Saunders… - Journal of Neural …, 2022 - iopscience.iop.org
Signal quality measures for six subjects (S1–6) over time; (A) … , acute inflammation (caused
by infection), in addition to bone … EEG and impedance recordings using a two-channel ring …

Flexible multi-layer semi-dry electrode for scalp EEG measurements at hairy sites

H Hua, W Tang, X Xu, DD Feng, L Shu - Micromachines, 2019 - mdpi.com
… , the electrodescalp impedances of most dry electrodes are … irritate the scalp and is associated
with a risk of infection due … EEG signals in static test conditions, and the signal quality is …

Comparison of electrode technologies for dry and portable EEG acquisition

M O'Sullivan, JP Pena, A Bocchino… - 2017 7th IEEE …, 2017 - ieeexplore.ieee.org
… a large input impedance, a skin-electrode impedance of less … as a method to objectively
quantify EEG signal quality [9], [24]. … , "Scalp electrode impedance, infection risk, and EEG data