Tris-acryl gelatin microspheres versus gelatin sponge particles in uterine artery embolization for leiomyoma

T Katsumori, H Miura, H Arima, A Hino… - Acta …, 2017 - journals.sagepub.com
… on magnetic resonance imaging (MRI) and the clinical success of … including embolic agents
and subsequent follow-up … subserosal leiomyoma and co-existing adenomyosis unlikely …

Comparison of pain within 24 h after uterine artery embolization with tris-acryl gelatin microspheres versus gelatin sponge particles for leiomyoma

T Katsumori, H Arima, S Asai, N Hayashi… - … Interventional Radiology, 2017 - Springer
… in UAE in terms of MR imaging and clinical outcomes [23]. … follow-up and opt-out consent
for the retrospective use of data… UAE and 2 with dominant adenomyosis) were excluded from …

[HTML][HTML] Uterine artery embolization with highly compressible calibrated microspheres for the treatment of uterine fibroids

D Szejnfeld, RFT Santos, AM Kambara… - Radiologia …, 2022 - SciELO Brasil
tris-acryl gelatin microspheres for uterine artery embolization … myometrial ischemia on
magnetic resonance imaging. J Vasc … -term clinical follow-up and the relatively small sample size. …

[HTML][HTML] Uterine artery embolization using gelatin sponge particles for symptomatic focal and diffuse adenomyosis

JY Kim, YG Song, CW Kim, MO Lee - Clinical and Experimental …, 2021 - imrpress.com
… For this study, MR imaging images were evaluated by two … by the procedure and at the
3-month follow-up MR imaging. … PVA particles or tris-acryl gelatin microspheres, with variable …

The evaluation of uterine artery embolization as a nonsurgical treatment option for adenomyosis

S Wang, X Meng, Y Dong - International Journal of Gynecology & …, 2016 - Elsevier
… 700-μm tris-acryl gelatin microspheres. At baseline, and 3, 6, and 12 months after UAE,
magnetic resonance imaging was used to assess uterine … Additionally, 3-year follow-up data was …

Uterine artery embolization for the treatment of adenomyosis: a systematic review and meta-analysis

AM de Bruijn, M Smink, PNM Lohle, JAF Huirne… - … Interventional Radiology, 2017 - Elsevier
fibroids in terms of symptom improvement and MR imaging … pure and combined adenomyosis
for every follow-up moment. … ; no studies reported data on patients lost to follow-up; some …

[HTML][HTML] Predisposing factors for predicting the therapeutic response of adenomyosis after uterine artery embolization: serum CA125 levels and accompanying …

R Zheng, D Zeng, TT Wan, WB Guo… - … Radiology, 2018 - ncbi.nlm.nih.gov
… with adenomyosis who underwent UAE with tris-acryl gelatin … value of preprocedural magnetic
resonance imaging (MRI) … (12-month) follow-up for patients with adenomyosis who have …

Fertility after uterine artery embolization for symptomatic multiple fibroids with no other infertility factors

A Torre, A Fauconnier, V Kahn, O Limot, L Bussierres… - … radiology, 2017 - Springer
… centres underwent pelvic magnetic resonance imaging (MRI), … We intended to contact women
lost to follow-up by phone … sparing embolization method with tris-acryl gelatin microspheres

Nomogram for predicting the long-term outcomes of uterine artery embolization for adenomyosis

J WenTao, Z GuoFu, W TianPin, W ShiJia… - … Journal of Radiology, 2022 - Elsevier
Tris-acryl gelatin microspheres (TGM) and polyvinyl alcohol … and magnetic resonance imaging
(MRI) findings of adenomyosis … A total of 201 patients completed a median follow-up of 37 …

Uterine artery embolisation: fertility, adenomyosis and size–what is the evidence?

L Mailli, S Patel, R Das, JY Chun, S Renani, S Das… - CVIR …, 2023 - Springer
… assessment with a 24 month follow up period and imaging follow up. … In studies to date,
the use of medium sized particles such as tris-acryl gelatintris-acryl gelatin microspheres