[HTML][HTML] Intrinsic antitachycardia pacing for patients with multiple ventricular tachycardias

K Okubo, E Nakashima, K Takagi, N Kawaguchi… - HeartRhythm Case …, 2022 - Elsevier
Antitachycardia pacing (ATP) offers a safe and painless termination of ventricular tachycardia
(… Intrinsic antitachycardia pacing (iATP) provides an automatic and tailored ATP for each VT …

Failure of intrinsic antitachycardia pacing to terminate ventricular tachycardia and potential proarrhythmic effects

A Raina, M van Zyl, M Henrich, AJ Deshmukh… - Clinical …, 2023 - jacc.org
antitachycardia pacing (ATP). The fourth round of ATP resulted in acceleration and degeneration
into ventricular fibrillation (… a proarrhythmic effect, intrinsic antitachycardia pacing (iATP) …

[HTML][HTML] Successful termination of ventricular tachycardia with intrinsic anti-tachycardia pacing

I Morishima, Y Kanzaki, Y Morita, Y Tsuji - Indian Pacing and …, 2021 - Elsevier
Intrinsic anti-tachycardia pacing (iATP) is a novel automated ATP algorithm that employs
post-pacing interval (PPI) to design the next ATP sequence based on an analysis of the prior …

Intrinsic anti-tachycardia pacing terminated ventricular tachycardia resistant to traditional anti-tachycardia pacing

H Hagiwara, M Watanabe, R Kamada… - Indian Pacing and …, 2022 - Elsevier
… Schematic diagram showing how the intrinsic anti-tachycardia pacing algorithm terminates
ventricular tachycardia. The antidromic wave collides with the active front of the previous …

Efficacy of intrinsic antitachycardia pacing for ventricular tachycardia refractory to conventional burst pacing: A case series

T Kamakura, N Ueda, M Wada… - Journal of …, 2023 - Wiley Online Library
Intrinsic antitachycardia pacing (iATP) is a novel automated ventricular ATP algorithm that …
have shown the efficacy of iATP for ventricular tachycardia (VT) refractory to conventional ATP …

Case report: successful termination of ventricular tachycardia by intrinsic anti-tachycardia pacing beyond conventional anti-tachycardia pacing

S Kazawa, K Satomi, H Murakami… - … Heart Journal-Case …, 2023 - academic.oup.com
… A ventricular tachycardia cycle length of 310 ms was detected when the first intrinsic anti-tachycardia
pacing was delivered. The first intrinsic anti-tachycardia pacing sequence …

Comparison of novel intrinsic versus conventional antitachycardia pacing for ventricular tachycardia among implantable cardioverter‐defibrillator recipients

S Yanagisawa, Y Inden, Y Sato… - Journal of …, 2024 - Wiley Online Library
… We excluded patients with only ventricular fibrillation (VF) events during the follow-up. All
patients received dual-chamber ICDs, and a right ventricular defibrillator lead was implanted in …

[HTML][HTML] … implantable cardioverter-defibrillator settings to intrinsic antitachycardia pacing–like settings in the treatment of ventricular tachycardia in patients with cardiac …

M Tachibana, A Hayashida, K Banba, M Arimichi… - HeartRhythm Case …, 2022 - Elsevier
… Using an approximation of the intrinsic antitachycardia pacing (iATP) formula, the
number of antitachycardia pacing (ATP) pulses required to reach the ventricular tachycardia …

Acute management of ventricular tachycardia

T Deneke, K Nentwich, E Ene, A Berkovitz… - …, 2020 - Springer
… Termination is best performed by electrical cardioversion, anti-tachycardia pacing (if … (if
available) and after termination of VA in intrinsic rhythm is crucial in detecting, for example…

… of the Novel Automated Anti-Tachycardia Pacing Algorithm Successfully Terminating Sustained Monomorphic Ventricular Tachycardia in an Electrophysiology Study …

S Yanagisawa, Y Inden, T Okajima… - International Heart …, 2022 - jstage.jst.go.jp
… We report the usefulness of novel automated anti-tachycardia pacing (ATP) for ventricular
tachycardia (VT) termination evaluated in an electrophysiology study. This intrinsic, automated …