Dynamic spiral MRI of pulmonary gas flow using hyperpolarized 3He: Preliminary studies in healthy and diseased lungs

M Salerno, TA Altes, JR Brookeman… - … in Medicine: An …, 2001 - Wiley Online Library
An optimized interleaved‐spiral pulse sequence, providing high spatial and temporal
resolution, was developed for dynamic imaging of pulmonary ventilation with hyperpolarized …

Pulmonary hyperpolarized noble gas MRI: recent advances and perspectives in clinical application

Z Liu, T Araki, Y Okajima, M Albert, H Hatabu - European journal of …, 2014 - Elsevier
The invention of hyperpolarized (HP) noble gas MRI using helium-3 (3 He) or xenon-129
(129 Xe) has provided a new method to evaluate lung function. Using HP 3 He or 129 Xe for …

Comparison of hyperpolarized 3He MRI with Xe‐enhanced computed tomography imaging for ventilation mapping of rat lung

GE Santyr, MJ Couch, WW Lam, A Ouriadov… - NMR in …, 2011 - Wiley Online Library
Lung ventilation was mapped in five healthy Brown Norway rats (210–377 g) using both
hyperpolarized 3He MRI and Xe‐enhanced computed tomography (Xe‐CT) under similar …

[PDF][PDF] Real-time MR imaging of pulmonary gas-flow dynamics with hyperpolarized 3He

K Ruppert, JR Brookeman, JP Mugler - … of the 6th Annual Meeting of …, 1998 - Citeseer
MR studies of the human lung with hyperpolarized 3 He have demonstrated the potential to
acquire high-resolution, but static, images of lung ventilation [1-3]. Given the high signal …

Regional anisotropy of airspace orientation in the lung as assessed with hyperpolarized helium‐3 diffusion MRI

P Komlosi, TA Altes, K Qing, KE Mooney… - Journal of Magnetic …, 2015 - Wiley Online Library
Purpose To evaluate regional anisotropy of lung‐airspace orientation by assessing the
dependence of helium‐3 (3He) apparent diffusion coefficient (ADC) values on the direction …

Quantification of pulmonary functional MRI: state-of-the-art and emerging image processing methods and measurements

M Sharma, PV Wyszkiewicz… - Physics in Medicine …, 2022 - iopscience.iop.org
Pulmonary functional magnetic resonance imaging (PfMRI) provides a way to non-invasively
map and measure the spatial distribution of pulmonary ventilation, perfusion and gas …

Imaging alveolar–capillary gas transfer using hyperpolarized 129Xe MRI

B Driehuys, GP Cofer, J Pollaro… - Proceedings of the …, 2006 - National Acad Sciences
Effective pulmonary gas exchange relies on the free diffusion of gases across the thin tissue
barrier separating airspace from the capillary red blood cells (RBCs). Pulmonary …

Simultaneous assessment of both lung morphometry and gas exchange function within a single breath‐hold by hyperpolarized 129Xe MRI

J Zhong, H Zhang, W Ruan, J Xie, H Li… - NMR in …, 2017 - Wiley Online Library
During the measurement of hyperpolarized 129Xe magnetic resonance imaging (MRI), the
diffusion‐weighted imaging (DWI) technique provides valuable information for the …

Quantification of Ventilation and Gas Uptake in Free-Breathing Mice With Hyperpolarized 129Xe MRI

LA Loza, SJ Kadlecek, M Pourfathi… - IEEE transactions on …, 2019 - ieeexplore.ieee.org
Hyperpolarized 129 Xe magnetic resonance imaging is a powerful modality capable of
assessing lung structure and function. While it has shown promise as a clinical tool for the …

Quantitative assessment of lung ventilation and microstructure in an animal model of idiopathic pulmonary fibrosis using hyperpolarized gas MRI

MJ Stephen, K Emami, JM Woodburn, E Chia… - Academic radiology, 2010 - Elsevier
RATIONALE AND OBJECTIVES: The use of hyperpolarized 3He magnetic resonance
imaging as a quantitative lung imaging tool has progressed rapidly in the past decade …