Experience of the combined use of the cusp-overlap projection and auricular pacing in transcatheter aortic-valve replacement with the self-expanding valves
M Tamargo, E Gutierrez, ME Vazquez… - European Heart …, 2022 - academic.oup.com
Introduction Need of permanent pacemaker implantation (PPI) continues to be an
undesirable side-effect after transcatheter aortic-valve replacement (TAVR), mostly in self …
undesirable side-effect after transcatheter aortic-valve replacement (TAVR), mostly in self …
Cusp overlap method for self‐expanding transcatheter aortic valve replacement
TF Aljabbary, I Komatsu, T Ochiai… - Catheterization and …, 2024 - Wiley Online Library
Background Conduction disturbances and the need for permanent pacemaker (PPM)
implantation remains a common complication for transcatheter aortic valve replacement …
implantation remains a common complication for transcatheter aortic valve replacement …
CRT-700.17 The Impact of the Cusp Overlap Technique on Permanent Pacemaker Requirement Following Transcatheter Aortic Valve Replacement With a Self …
GA Medranda, T Rogers, BC Case, C Zhang… - Cardiovascular …, 2023 - jacc.org
Background The cusp overlap technique has standardized implantation for self-expanding
valves with the goal to achieve more consistent implantation depths and to lower permanent …
valves with the goal to achieve more consistent implantation depths and to lower permanent …
Trends in permanent pacemaker implantation in transcatheter aortic valve replacement using the cusp overlap technique: insights from the eprompt registry
Background: Despite advancements in self-expanding transcatheter heart valve (THV)
design, conduction disturbances following contemporary transcatheter aortic valve …
design, conduction disturbances following contemporary transcatheter aortic valve …
The impact of the cusp overlap technique on permanent pacemaker requirement following transcatheter aortic valve replacement with a self-expanding valve: single …
G Medranda, T Rogers, B Case, C Zhang… - Journal of the American …, 2023 - jacc.org
Background Recently, the cusp overlap technique has emerged as a standardized
technique aimed at producing more consistent deployment and accurate implantation …
technique aimed at producing more consistent deployment and accurate implantation …
Cusp-overlap view reduces conduction disturbances and permanent pacemaker implantation after transcatheter aortic valve replacement even with balloon …
T Stephan, M Krohn-Grimberghe… - Frontiers in …, 2023 - frontiersin.org
Background Conduction disturbances demanding permanent pacemaker implantation (PPI)
remain a common complication after transcatheter aortic valve replacement (TAVR) …
remain a common complication after transcatheter aortic valve replacement (TAVR) …
TCT CONNECT-467 A Simple and Reproducible Method to Reduce Pacemaker Rates Post-Transcatheter Aortic Valve Replacement With Self-Expandable Valves
Background While the indications of transcatheter aortic valve replacement (TAVR) with self-
expandable valves (SEV) have recently expanded to low-risk patients, high rates of …
expandable valves (SEV) have recently expanded to low-risk patients, high rates of …
Low rates of permanent pacing are observed following self-expanding transcatheter aortic valve replacement using an annular plane projection for deployment
AD Pisaniello, HBE Makki, S Jahangeer… - Circulation …, 2021 - Am Heart Assoc
Balloon-expandable valves exert higher radial forces than self-expanding (SE) transcatheter
heart valves (THVs), 2 but permanent pacemaker implantation (PPI) rates are higher after …
heart valves (THVs), 2 but permanent pacemaker implantation (PPI) rates are higher after …
Long-term clinical impact of permanent cardiac pacing after transcatheter aortic valve implantation with the CoreValve prosthesis: a single center experience
J López-Aguilera, JM Segura Saint-Gerons… - EP …, 2018 - academic.oup.com
Aims To determine the impact of permanent cardiac pacing after transcatheter aortic valve
implantation (TAVI) with the CoreValveTM prosthesis in terms of all-cause mortality and …
implantation (TAVI) with the CoreValveTM prosthesis in terms of all-cause mortality and …
[PDF][PDF] Impact of Cusp-Overlap Technique on Pacemaker Requirement after Transcatheter Aortic Valve Implantation
M SZTEJFMAN, CM GIULIANI, S PERALTA… - Revista Argentina …, 2021 - old2.sac.org.ar
Background: Persistent bradyarrhythmias requiring permanent pacemaker implantation are
a common complication after transcatheter aortic valve implantation (TAVI), but high …
a common complication after transcatheter aortic valve implantation (TAVI), but high …