[PDF][PDF] Evaluation of the implant electrode inside the cochlea and damage to cochlear structures associated with implantation using cone beam computed tomography …
A Orłowski, M Lachowska, E Wiśniewska… - Polski Przegląd …, 2016 - bibliotekanauki.pl
Objectives: The aim was to evaluate the position of the cochlear implant electrode inside the
cochlea and damage to cochlear structures associated with the implantation itself using …
cochlea and damage to cochlear structures associated with the implantation itself using …
Radiological evaluation of inner ear trauma after cochlear implant surgery by cone beam CT (CBCT)
Purpose Cochlear implantation (CI) has been extended to involve younger age group with
higher incidence of residual hearing which increases the need of minimizing surgical inner …
higher incidence of residual hearing which increases the need of minimizing surgical inner …
Artifacts of the electrode in cochlea implantation and limits in analysis of deep insertion in cone beam tomography (CBT)
C Güldner, S Wiegand, R Weiss, S Bien… - European Archives of …, 2012 - Springer
Until now more than 250,000 cochlea implantations have been performed worldwide. The
surgical procedure is well standardized. A discussion about the kind of postoperative …
surgical procedure is well standardized. A discussion about the kind of postoperative …
Evaluation of artifacts of cochlear implant electrodes in cone beam computed tomography
Abstract Purpose Cone Beam Computed Tomography (CBCT) offers a valid alternative to
conventional Computed Tomography (CT). A possible radiation dose reduction with the use …
conventional Computed Tomography (CT). A possible radiation dose reduction with the use …
Cone beam computed tomography, a low-dose imaging technique in the postoperative assessment of cochlear implantation
J Ruivo, K Mermuys, K Bacher, R Kuhweide… - Otology & …, 2009 - journals.lww.com
Background: Cone beam computed tomography (CBCT) has become an extremely useful
technique for dentomaxillofacial imaging because it provides clear images of highly …
technique for dentomaxillofacial imaging because it provides clear images of highly …
Intraoperative evaluation of cochlear implant electrodes using mobile cone-beam computed tomography
N Yamamoto, T Okano, H Yamazaki… - Otology & …, 2019 - journals.lww.com
Objective: To evaluate the electrode status during cochlear implantation (CI) using mobile
cone-beam CT (mCBCT). Study Design: Retrospective case review. Setting: Tertiary referral …
cone-beam CT (mCBCT). Study Design: Retrospective case review. Setting: Tertiary referral …
Imaging procedures in cochlear implant patients–evaluation of different radiological techniques
A Aschendorff, R Kubalek, A Hochmuth… - Acta Oto …, 2004 - Taylor & Francis
The purpose of this study was to evaluate the feasibility and usability of different radiologic
methods (single-slice computed tomography (CT), multi-slice CT and rotational tomography …
methods (single-slice computed tomography (CT), multi-slice CT and rotational tomography …
Evaluation of the implanted cochlear implant electrode by CT scanning with three-dimensional reconstruction
WJ Kong, HM Cheng, H Ma, YJ Wang… - Acta oto …, 2012 - Taylor & Francis
Conclusions: Computed tomography (CT) scan with three-dimensional (3D) reconstruction
of the inner ear provides a more accurate image of the relationship of the electrode within …
of the inner ear provides a more accurate image of the relationship of the electrode within …
Intracochlear assessment of electrode position after cochlear implant surgery by means of multislice computer tomography
GKA van Wermeskerken, M Prokop… - European Archives of …, 2007 - Springer
The development of electrode arrays, the past years, has focused on modiolus-hugging
cochlear implant electrodes. Besides, atraumatic implantation of electrodes is of importance …
cochlear implant electrodes. Besides, atraumatic implantation of electrodes is of importance …
Automated calculation of cochlear implant electrode insertion parameters in clinical cone-beam CT
SAW Andersen, JP Keith, B Hittle, WJ Riggs… - Otology & …, 2022 - journals.lww.com
Background: Hearing outcomes after CI surgery are dependent on electrode placement.
CBCT is increasingly used for in-office temporal bone imaging and might be routinely used …
CBCT is increasingly used for in-office temporal bone imaging and might be routinely used …
相关搜索
- implant electrodes cone beam
- cochlear structures implant electrode
- cochlear structures cone beam
- implant electrodes computed tomography
- computed tomography cone beam
- implant electrodes intraoperative evaluation
- computed tomography intraoperative evaluation
- ear trauma cone beam
- intraoperative evaluation cone beam
- implant surgery electrode position
- radiological evaluation ear trauma
- implant surgery ear trauma
- implant surgery radiological evaluation
- cochlear implantation postoperative assessment
- postoperative assessment cone beam
- automated calculation cone beam