[HTML][HTML] Appropriate and inappropriate therapy in patients with single-or multi-chamber implantable cardioverter-defibrillators

AL Burger, H Schmidinger, R Ristl… - Hellenic Journal of …, 2020 - Elsevier
Background Inappropriate ICD therapy is associated with adverse outcome. Previous
studies indicated that patients with a cardiac resynchronization therapy-defibrillator (CRT-D) …

Frequency of inappropriate therapy in patients implanted with dual‐versus single‐chamber ICD devices in the ICD arm of MADIT‐CRT

ACH RUWALD, N Sood, MH Ruwald… - Journal of …, 2013 - Wiley Online Library
Inappropriate Therapy in Single Versus Dual Chamber Background The majority of
implantable cardioverter defibrillators (ICDs) are dual‐chamber devices, but studies on the …

[HTML][HTML] Risk factors for the first and second inappropriate implantable cardioverter-defibrillator therapy

N Nishii, T Noda, T Nitta, Y Aizawa, T Ohe… - IJC Heart & Vasculature, 2021 - Elsevier
Introduction Various risk factors for the first inappropriate implantable cardioverter-
defibrillator (ICD) therapy event have been reported, including a history of atrial …

Clinical Outcomes of Single‐versus Dual‐Chamber Implantable Cardioverter Defibrillators: Lessons from the Israeli ICD Registry

Y Konstantino, M Haim, J Boxer… - Journal of …, 2016 - Wiley Online Library
Clinical Outcome of Single‐versus Dual‐Chamber ICDs Objective To compare the clinical
outcomes of a single‐versus dual‐chamber ICD for primary prevention of sudden cardiac …

Mortality and appropriate and inappropriate therapy in patients with ischaemic heart disease and implanted cardioverter-defibrillators for primary prevention: data from …

P Weeke, JB Johansen, OD Jørgensen, JC Nielsen… - Europace, 2013 - academic.oup.com
Aims To evaluate the incidences of and risk factors predisposing to appropriate and
inappropriate shocks and mortality in a 'real-world'population of patients with ischaemic …

Lower incidence of inappropriate shock therapy in patients with combined cardiac resynchronisation therapy defibrillators (CRT‐D) compared with patients with non …

Z Chen, T Kotecha, S Crichton, A Shetty… - … Journal of Clinical …, 2013 - Wiley Online Library
Introduction: A significant number of patients experience inappropriate shock therapy (IST)
from implantable cardioverter‐defibrillators (ICD). An increasing number of patients with …

Reduced risk for inappropriate implantable cardioverter-defibrillator shocks with dual-chamber therapy compared with single-chamber therapy: results of the …

C Kolb, M Sturmer, P Sick, S Reif, JM Davy, G Molon… - JACC: Heart Failure, 2014 - jacc.org
Abstract Objectives: The OPTION (Optimal Anti-Tachycardia Therapy in Implantable
Cardioverter-Defibrillator Patients Without Pacing Indications) trial sought to compare long …

Association of single-vs dual-chamber ICDs with mortality, readmissions, and complications among patients receiving an ICD for primary prevention

PN Peterson, PD Varosy, PA Heidenreich, Y Wang… - JAMA, 2013 - jamanetwork.com
Importance Randomized trials of implantable cardioverter-defibrillators (ICDs) for primary
prevention predominantly used single-chamber devices. In clinical practice, patients often …

Comparison of inappropriate shocks and other health outcomes between single‐and dual‐chamber implantable cardioverter‐defibrillators for primary prevention of …

PN Peterson, RT Greenlee, AS Go… - Journal of the …, 2017 - Am Heart Assoc
Background In US clinical practice, many patients who undergo placement of an implantable
cardioverter‐defibrillator (ICD) for primary prevention of sudden cardiac death receive dual …

Dual-vs. single-chamber defibrillators for primary prevention of sudden cardiac death: long-term follow-up of the Défibrillateur Automatique Implantable—Prévention …

P Defaye, S Boveda, D Klug, F Beganton, O Piot… - EP …, 2017 - academic.oup.com
Abstract Aims Implantable cardioverter defibrillators (ICDs) are an effective primary
prevention of sudden cardiac death. We examined whether dual-chamber (DC) ICDs confer …