Comparison of novel intrinsic versus conventional antitachycardia pacing for ventricular tachycardia among implantable cardioverter‐defibrillator recipients
S Yanagisawa, Y Inden, Y Sato… - Journal of …, 2024 - Wiley Online Library
Introduction Intrinsic antitachycardia pacing (iATP) is a novel automated antitachycardia
pacing (ATP) that provides individual treatment to terminate ventricular tachycardia (VT) …
pacing (ATP) that provides individual treatment to terminate ventricular tachycardia (VT) …
Efficacy of intrinsic antitachycardia pacing for ventricular tachycardia refractory to conventional burst pacing: A case series
T Kamakura, N Ueda, M Wada… - Journal of …, 2023 - Wiley Online Library
Intrinsic antitachycardia pacing (iATP) is a novel automated ventricular ATP algorithm that
designs ATP sequences based on the analysis of prior failed ATP. Real‐world data on the …
designs ATP sequences based on the analysis of prior failed ATP. Real‐world data on the …
[HTML][HTML] Intrinsic antitachycardia pacing for patients with multiple ventricular tachycardias
K Okubo, E Nakashima, K Takagi, N Kawaguchi… - HeartRhythm Case …, 2022 - Elsevier
Antitachycardia pacing (ATP) offers a safe and painless termination of ventricular
tachycardia (VT) in patients with implantable cardioverter-defibrillators (ICDs). 1 However, it …
tachycardia (VT) in patients with implantable cardioverter-defibrillators (ICDs). 1 However, it …
Failure of intrinsic antitachycardia pacing to terminate ventricular tachycardia and potential proarrhythmic effects
A Raina, M van Zyl, M Henrich, AJ Deshmukh… - Clinical …, 2023 - jacc.org
Intrinsic antitachycardia pacing (iATP) is a novel, automated antitachycardia pacing (ATP)
algorithm that provides individualized therapy to terminate ventricular tachycardia (VT). If the …
algorithm that provides individualized therapy to terminate ventricular tachycardia (VT). If the …
PO-05-056 FAILURE OF INTRINSIC ANTI-TACHYCARDIA PACING TO TERMINATE VENTRICULAR TACHYCARDIA AND POTENTIAL PROARRHYTHMIC …
A Raina, M van Zyl, MJ Henrich… - Heart …, 2023 - heartrhythmjournal.com
Background Intrinsic anti-tachycardia pacing (iATP™) is a novel, automated ATP algorithm
that provides individualized therapy to terminate ventricular tachycardia (VT). If the first ATP …
that provides individualized therapy to terminate ventricular tachycardia (VT). If the first ATP …
Long-term efficacy of antitachycardia pacing for treatment of ventricular tachycardia in patients with implantable cardioverter/defibrillator
M Fiek, E Hoffmann, U Dorwarth, D Müller… - Zeitschrift fur …, 1999 - europepmc.org
Conclusions First, ATP is a highly effective therapy, independent of patients characteristics.
Second, short VT cycle length and long ATP coupling intervals were identified as predictors …
Second, short VT cycle length and long ATP coupling intervals were identified as predictors …
[HTML][HTML] Successful termination of ventricular tachycardia with intrinsic anti-tachycardia pacing
I Morishima, Y Kanzaki, Y Morita, Y Tsuji - Indian Pacing and …, 2021 - Elsevier
Intrinsic anti-tachycardia pacing (iATP) is a novel automated ATP algorithm that employs
post-pacing interval (PPI) to design the next ATP sequence based on an analysis of the prior …
post-pacing interval (PPI) to design the next ATP sequence based on an analysis of the prior …
Initial clinical experience with a new automated antitachycardia pacing algorithm: feasibility and safety in an ambulatory patient cohort
R Yee, JD Fisher, U Birgersdotter-Green… - Circulation …, 2017 - Am Heart Assoc
Background: Antitachycardia pacing (ATP) in implantable cardioverter-defibrillators (ICD)
decreases patient shock burden but has recognized limitations. A new automated ATP …
decreases patient shock burden but has recognized limitations. A new automated ATP …
Empirical versus tested antitachycardia pacing in implantable cardioverter defibrillators: a prospective study including 200 patients
A Schaumann, F Mühlen, B Herse, BD Gonska… - Circulation, 1998 - Am Heart Assoc
Background—Implantable cardioverter-defibrillators (ICDs) reduce the risk of sudden
cardiac death. The objective of this study was to evaluate whether testing of antitachycardia …
cardiac death. The objective of this study was to evaluate whether testing of antitachycardia …
Anti‐tachycardia pacing for non‐fast and fast ventricular tachycardias in individual Japanese patients: from Nippon‐storm study
M Chinushi, O Saitoh, H Furushima… - Journal of …, 2021 - Wiley Online Library
Background Anti‐tachycardia pacing (ATP) delivered from an implantable device is a useful
tool to terminate ventricular tachycardia (VT). But its real‐world efficacy for those patients …
tool to terminate ventricular tachycardia (VT). But its real‐world efficacy for those patients …
相关搜索
- ventricular tachycardia implantable cardioverter
- ventricular tachycardia defibrillator recipients
- antitachycardia pacing algorithm
- ventricular tachycardia successful termination
- intrinsic anti-tachycardia pacing
- ventricular tachycardia intrinsic antitachycardia
- ventricular tachycardia burst pacing
- efficacy of anti-tachycardia pacing