Correlation between pressure and volume parameters of septic shock patients with cardiac depression

HM Zhang, DW Liu, XT Wang, Y Long… - Zhonghua wai ke za …, 2010 - europepmc.org
Methods Seventy seven septic shock patients treated from January 2005 to June 2009 were
retrospectively studied, they were divided into two groups based on cardiac index (CI) after …

Circuit factors in the high cardiac output of sepsis

S Magder, G Vanelli - Journal of Critical Care, 1996 - Elsevier
Purpose: The increase of cardiac output (CO) in sepsis must be matched by an increase in
venous return. Our goal was to determine which of the determinants of venous return are …

Measurement of Ventilation-Perfusion Ratio Using Multiple Inert Gas Elimination Technique in the Endotoxin-Induced Septic Rabbit.

YB Jeong, JY Sim, SI Ha, IC Choi - Korean Journal of Anesthesiology, 2001 - ekja.org
BACKGROUND Endotoxin is a complex lipopolysaccharide molecule situated within the
outer membrane of Gram-negative bacteria. Sepsis and acute respiratory failure (ARDS) can …

An evaluation of the initial distribution volume of glucose to assess plasma volume during a fluid challenge

L van Tulder, B Michaeli, R Chioléro… - Anesthesia & …, 2005 - journals.lww.com
IMPLICATIONS: The initial distribution volume of glucose (IDVG) is supposed to reflect
effective circulating blood volume. We assessed the sensitivity of this method to a fluid …

The influence of positive end-expiratory pressure on stroke volume variation for the accuracy of evaluating volume

N Liu, Q Gu, JF Yu - Zhongguo wei Zhong Bing ji jiu yi xue= Chinese …, 2012 - europepmc.org
Objective To investigate the influence of positive end-expiratory pressure (PEEP) on
hemodynamic and the ability of stroke volume variation (SVV) to predict cardiac preload …

The initial distribution volume of glucose and cardiac output in the critically ill

H Ishihara, Y Shimodate, H Koh, K Isozaki… - Canadian journal of …, 1993 - Springer
Blood or plasma glucose concentration can be measured accurately and rapidly. However,
after a glucose challenge metabolism may modify glucose kinetics, so that glucose has not …

Central venous pressure in combination with visual left ventricular ejection fraction as an indicator of fluid responsiveness in patients with septic shock

J Duan, L Cong, D Chen, T LI, C LI… - Journal of Chinese …, 2015 - pesquisa.bvsalud.org
Objective To investigate the value of central venous pressure (CVP) combined with visual
left ventricular ejection fraction (LVEF) as an indicator of fluid responsiveness in patients …

Blood glucose increments as a measure of body physiology

RG Hahn - Critical Care, 2005 - Springer
The initial distribution volume of glucose (IDVG) can be calculated from the arterial plasma
glucose level between 3 and 7 min after a bolus intravenous infusion of 5 g glucose …

Left ventricular end-diastolic pressure-volume relationship in septic rats with open thorax

S Cesar, N Potocnik, V Starc - Comparative medicine, 2003 - ingentaconnect.com
To estimate changes in compliance, we evaluated the effects of sepsis on the end-diastolic
pressure-volume relationship (EDPVR) in the left ventricle of rats that had undergone an …

Contribution of peripheral blood pooling to central hemodynamic disturbances during endotoxin insult in intact dogs

V D'ORIO, C WAHLEN, M Naldi, A FOSSION… - Critical care …, 1989 - journals.lww.com
The aim of the present study was to determine possible effects of Escherichia coli endotoxin
on peripheral vascular compliance and relate them to concomitant central hemodynamic …