SESAME: a software tool for the numerical dosimetric reconstruction of radiological accidents involving external sources and its application to the accident in Chile in …

C Huet, A Lemosquet, I Clairand, JB Rioual… - Health …, 2009 - journals.lww.com
Estimating the dose distribution in a victim's body is a relevant indicator in assessing
biological damage from exposure in the event of a radiological accident caused by an …

All about MAX: a male adult voxel phantom for Monte Carlo calculations in radiation protection dosimetry

R Kramer, JW Vieira, HJ Khoury… - Physics in Medicine & …, 2003 - iopscience.iop.org
Abstract The MAX (Male Adult voXel) phantom has been developed from existing
segmented images of a male adult body, in order to achieve a representation as close as …

Experimental verification of a CT‐based Monte Carlo dose‐calculation method in heterogeneous phantoms

L Wang, M Lovelock, CS Chui - Medical physics, 1999 - Wiley Online Library
To further validate the Monte Carlo dose‐calculation method [Med. Phys. 25, 867–878
(1998)] developed at the Memorial Sloan‐Kettering Cancer Center, we have performed …

[引用][C] Voxel phantom setup in MCNPX

V Taranenko, M Zankl, H Schlattl - Proc. Monte Carlo 2005 topical meeting. The …, 2005

[引用][C] Reply toComments onConverting absorbed dose to medium to absorbed dose to water for Monte Carlo based photon beam dose calculations''

JV Siebers, PJ Keall, AE Nahum… - Physics in Medicine & …, 2000 - iopscience.iop.org
Fippel and Nüsslin raise some interesting points regarding Monte Carlo dose calculation in
their letter—points that certainly should be considered for all Monte Carlo dose calculation …

Development of a web-based CT dose calculator: WAZA-ARI

N Ban, F Takahashi, K Sato, A Endo… - Radiation protection …, 2011 - academic.oup.com
A web-based computed tomography (CT) dose calculation system (WAZA-ARI) is being
developed based on the modern techniques for the radiation transport simulation and for …

MCMEG: Simulations of both PDD and TPR for 6 MV LINAC photon beam using different MC codes

TCF Fonseca, BM Mendes, MAS Lacerda… - Radiation Physics and …, 2017 - Elsevier
Abstract The Monte Carlo Modelling Expert Group (MCMEG) is an expert network
specializing in Monte Carlo radiation transport and the modelling and simulation applied to …

Comparison of normal tissue dose calculation methods for epidemiological studies of radiotherapy patients

MM Mille, JW Jung, C Lee, GA Kuzmin… - Journal of Radiological …, 2018 - iopscience.iop.org
Radiation dosimetry is an essential input for epidemiological studies of radiotherapy patients
aimed at quantifying the dose–response relationship of late-term morbidity and mortality …

Voxel phantoms and Monte Carlo methods applied to in vivo measurements for simultaneous 241Am contamination in four body regions

J G. Hunt, B M. Dantas, M C. Lourenço… - Radiation protection …, 2003 - academic.oup.com
Abstract A Monte Carlo program, Visual Monte Carlo (VMC) in vivo, was written to simulate
photon transport through an anthropomorphic phantom and to detect radiation emitted from …

[图书][B] Assessment of organ doses from exposure to neutrons using the Monte Carlo technique and an image-based anatomical model

A Bozkurt - 2000 - search.proquest.com
The distribution of absorbed doses in the body can be computationally determined using
mathematical or tomographic representations of human anatomy. A whole-body model was …